YB Series Prefabricated Substation

YB Series Prefabricated Substation

YB prefabricated substation muaj cov yam ntxwv ntawm kev ua tiav muaj zog, me me, cov qauv compact, kev nyab xeeb thiab txhim khu kev qha, kev saib xyuas yooj yim, thiab kev txav mus los.
Xa kev nug
Tsham tam sim no

Muaj lus nug? GNEE cov neeg muag khoom muaj nyob rau hauv kev sib tham tam sim no

Xa E-mail:sales@gneeelectric.com

Tel:+8615824687445

 

YB seriesprefabricated substationyog cov khoom siv hluav taws xob ua tiav cov khoom siv hluav taws xob sib txuas ua ke nrog cov khoom siv hluav taws xob hluav taws xob, cov khoom siv hluav taws xob, cov khoom siv hluav taws xob tsawg, thiab lwm yam., nws tuaj yeem siv rau hauv cov tsev siab siab hauv nroog, nroog thiab cov tsev nyob deb nroog, cov tsev nyob hauv tsev, cov chaw tsim kho high-tech. , me me thiab nruab nrab cov chaw tsim khoom, mining thiab roj teb, thiab kev siv hluav taws xob ib ntus thiab lwm qhov chaw, nrog rau kev txais thiab xa tawm hluav taws xob hauv lub zog hluav taws xob.

Lub luag haujlwm tseem ceeb

Lub npe Chav tsev Cov khoom siv hluav taws xob hluav taws xob siab Hloov pauv  

Rated voltage

kV ua 10 10,0.4 0.4

Rated tam sim no

A 630   100~2500

Rated zaus

Hz 50 50 50

Rated peev

kVA ua   100~1250  

Rated thermal stability tam sim no

kA 20/4S   30/1S

Rated dynamic stability tam sim no (nce tus nqi)

kA 50   63

Rated ua luv-circuit tam sim no (peak value)

kA 50   15~30

Rated tawg luv-circuit tam sim no

kA 31.5 (Fuse)    

Rated tawg load tam sim no

A 630    

1 min fais fab zaus withstand voltage

kV ua

Mus rau hauv av, interphase 42, interphase 48

35/28 (5 feeb) 20/2.5

Lightning impulse withstand voltage

kV ua Rau hauv av, interphase 75, interphase 85 75  

Shell tiv thaiv qib

  IP23 IP23 IP23

Lub suab nrov

dB  

Roj transformer Tsawg dua lossis sib npaug rau 55,

Qhuav transformer Tsawg dua los yog sib npaug rau 65

 

Tus naj npawb ntawm circuits

Chav tsev 1~6

2

4~30

Maximum reactive them nyiaj nyob rau sab qis-voltage

kvar     300

Compact transformer substation

Prefabricated substation nta

1. Cov khoom no yog tsim los ntawm high-voltage fais fab faib khoom, transformer thiab low-voltage fais fab faib khoom. Nws tau muab faib ua peb qhov chaw ua haujlwm, uas yog, qhov siab-voltage compartment, transformer compartment thiab low-voltage compartment. Cov high-voltage thiab low-voltage compartments muaj cov haujlwm tiav. Lub hauv paus fais fab mov ntawm lub high-voltage sab tuaj yeem npaj rau hauv ntau hom kev siv hluav taws xob, xws li lub tshuab hluav taws xob sib txuas, lub tshuab hluav taws xob, lub zog hluav taws xob, ob lub zog hluav taws xob, thiab lwm yam. ua tau raws li qhov xav tau ntawm high-voltage metering. S9, SC thiab lwm yam ntawm cov roj poob qis rau hauv transformers lossis qhuav-hom transformers tuaj yeem xaiv rau chav hloov pauv; Raws li tus neeg siv khoom xav tau, chav tsev tsis muaj hluav taws xob tuaj yeem txais yuav vaj huam sib luag lossis txee mounted qauv los tsim cov qauv siv hluav taws xob xav tau los ntawm tus neeg siv. Nws muaj ntau yam haujlwm xws li kev faib hluav taws xob, teeb pom kev zoo, kev them nyiaj rov qab ua haujlwm, hluav taws xob ntsuas hluav taws xob thiab ntsuas hluav taws xob kom tau raws li cov neeg siv khoom sib txawv. Nws kuj yog qhov yooj yim rau cov neeg siv los tswj cov khoom siv hluav taws xob thiab txhim kho cov khoom siv hluav taws xob zoo.

2. Lub high-voltage chamber muaj ib tug compact thiab tsim nyog cov qauv, thiab muaj ib tug kev tiv thaiv kev ua tsis zoo linkage muaj nuj nqi. Thaum xav tau los ntawm tus neeg siv, lub tshuab hloov pauv tuaj yeem nruab nrog cov ntsia hlau kom yooj yim nkag los ntawm lub rooj vag ntawm ob sab ntawm chav tsev transformer. Txhua chav yog nruab nrog cov khoom siv teeb pom kev zoo. Tsis tas li ntawd, tag nrho cov ntsiab lus xaiv rau chav tsev siab thiab tsis tshua muaj hluav taws xob muaj kev ntseeg siab hauv kev ua haujlwm thiab kev ua haujlwm yooj yim, ua rau cov khoom muaj kev nyab xeeb thiab txhim khu kev qha hauv kev ua haujlwm thiab yooj yim rau kev tswj.

3. Kev ua kom cua thiab yuam kev cua tau txais yuav. Chav tsev transformer thiab cov chav siab thiab tsis tshua muaj hluav taws xob tau nruab nrog cov qhov cua nkag, thiab cov kiv cua tso tawm tau nruab nrog cov cuab yeej ntsuas kub uas tuaj yeem pib thiab kaw raws li qhov ntsuas kub kom ntseeg tau tias kev ua haujlwm ntawm lub tshuab hloov pauv.

4. Lub thawv qauv tuaj yeem tiv thaiv cov dej nag thiab av los ntawm kev nkag mus, thiab cov ntaub ntawv yog ua los ntawm cov xim hlau phaj nrog kev tiv thaiv corrosion thiab thermal rwb thaiv tsev ua haujlwm. Nws muaj cov xwm txheej rau kev siv sab nraum zoov mus sij hawm ntev kom ntseeg tau tias muaj kev tiv thaiv corrosion, dej tsis zoo thiab plua plav pov thawj, kev ua haujlwm ntev thiab zoo nkauj tsos.

Ntim & Shipping

Compact substation unit

Cim npe nrov: yb series prefabricated substation, Tuam Tshoj yb series prefabricated substation manufacturers, lwm tus neeg, Hoobkas

Xa kev nug