Dab tsi yog Pad Mounted Transformer

 

 

Pad mounted transformer yog hauv av-mounted hluav taws xob faib hluav taws xob transformer nyob rau hauv lub xauv steel txee mounted rau ntawm lub pob zeb.

 

Cov txiaj ntsig ntawm Pad Mounted Transformer

 

 

Kev nyab xeeb nta
Pad mounted transformers yog tsim los nrog kev nyab xeeb raws li qhov tseem ceeb. Lawv cov qauv uas nyob ib puag ncig tiv thaiv kev sib cuag nrog cov khoom nyob, txo qhov kev pheej hmoo ntawm hluav taws xob poob siab.

 

Aesthetic cuam tshuam
Cov transformers no paub txog lawv qhov tsawg -profile thiab compact design, uas tso cai rau lawv mus muab sib xyaw rau hauv ntau qhov chaw seamlessly dua lwm hom transformers.

 

Kev ntseeg tau thiab kav ntev
Tsim los tiv thaiv ib puag ncig hnyav, ncoo mounted transformers khav theeb tsim muaj zog, pab txhawb rau lawv. Lawv tiv taus huab cua, kev ua phem, thiab kev cuam tshuam ntawm cov tsiaj qus, kom ntseeg tau tias muaj zog thiab txhim khu kev qha nyob rau lub sijhawm.

 

Yooj yim ntawm installation thiab txij nkawm
Hauv av- theem kev tso kawm ntawm ncoo mounted transformers ua kom yooj yim rau txoj kev teeb tsa, tsuas yog xav tau ib lub pob zeb thiab cov hluav taws xob sib txuas. Qhov kev siv tau yooj yim no tseem ua rau kev saib xyuas niaj hnub thiab kev tshuaj xyuas yooj yim dua, txo cov nqi khiav lag luam thiab tsawg dua sijhawm.

 

Txhim khu kev ruaj ntseg
Cov lockable enclosures ntawm ncoo mounted transformers muab ib txheej ntxiv ntawm kev ruaj ntseg, tiv thaiv tsis tau tso cai nkag thiab tampering. Qhov no yog qhov tseem ceeb tshwj xeeb hauv cov cheeb tsam uas muaj kev cuam tshuam rau kev ua phem los yog qhov chaw muaj kev nyab xeeb rau pej xeem.

  • 250 KVA ncoo ntsia hloov pauv

    250 Kva ncoo Makeded Transformer muaj thawj voltage ntawm 270/24000}}}}}}}}}}}} {}} Peb kuj muaj cov khoom noj radial thiab tuag ua ntej thawj / nyob pem hauv ntej kev sib txuas.

  • 1.5 MVA ncoo - Mounted Transformer

    Lub 1.5 MVA ncoo {{1} mounted transformer kauj ruam nqis los ntawm 16,340V (HEEV Voltage) rau 480V (WALD) WEA). Nws muaj qhov kev sib txuas ntawm Delta thiab Wye kev sib txuas ntawm cov winding thib

  • 3000 KVA Pad-mounted Transformer

    Raws li qhov nruab nrab - qhov loj me ntawm lub peev xwm hloov hluav taws xob, 3000 kVA pad mounted transformer yog dav siv nyob rau hauv cov chaw xws li subway chaw nres tsheb, tshav dav hlau, tsev

  • 300 kva ncoo - Mounted Transformer

    300 kva ncoo {{{{{1} mounted transformer tsim thiab ntau dua li {}, thiab lwm yam, thiab thiab kuv daim ntawv pov thawj.

  • 4400 KVA Pad-mounted Transformer

    4400 kVA ncoo-mounted transformer yog Industrial Pad Mount Transformer uas muaj lub zog muaj zog, txhim khu kev qha, thiab muaj txiaj ntsig kev faib hluav taws xob hauv tsev, sab nraum zoov, thiab

  • 225 KVA Peb Theem Pad mounted Transformer

    225 KVA Peb theem peb theem txhaj tshuaj mounted transformer ua rau raws li cov qauv thoob ntiaj teb xws li Ansi / Ieee thiab CSA. Nws ua tau raws li Doe 2016 Qhov Yuav Tsum Tau Ua thiab muaj ntawv

  • 4200 KVA Pad-mounted Transformer

    Peb -theem ncoo- mounted transformers yog compact fais fab chaw rau kev siv hluav taws xob, kev lag luam lossis kev lag luam kev siv, tsim los tiv thaiv ntau qhov chaw ib puag ncig. Cov transformers

  • 150Kva ncoo - lub tshuab hloov pauv

    Lub 150 KVA Transformer yog ib qho peb theem, ncoo mounted transformer uas tau siv dav hauv cov hluav taws xob rau kev lag luam, lag luam nyob hauv North thiab South America. Gnee Transformers tsim

  • 75 KVA ncoo - lub tshuab hloov pauv

    75 KVA ncoo {{{{1} mounted transformer tsis tsuas yog ntsib thiab ntau dua li DEES, thiab lwm yam ntawv pov thawj kom ua kom cov khoom lag luam zoo thiab muaj kev nyab xeeb. Nws yog siv rau hauv cov

  • 5 mva ncoo {- lub tshuab hloov hluav taws xob

    5 mva ncoo {- lub tshuab hloov hluav taws xob. Thawj voltage: 22, 860} grdy / 13,200V. Voltage Thib Ob: 4,160 grdy / 2,400V. Vector pawg: Ynyn0

  • BESS Transformer

    Cov pad mounted transformer no yog tsim tshwj xeeb rau Battery Energy Storage System (BESS) fais fab chaw nres tsheb.A loj -scale BESS tsis tuaj yeem ua haujlwm yam tsis muaj kev sib txuas rau cov

  • 10 mva ncoo {- Mounted Transformer

    10 mva ncoo {- Mounted Transformer. Kev ntsuas thawj cov hluav taws xob: 34.5-19.92 / 13.8-7.957 / 13.2-7.62 / 12.47-7.2 lossis lwm tus. Kev Ntsuas Hluav Taws Xob Thib Ob: 208Grro / 120;

Vim Li Cas Xaiv Peb

 

 

Kev Txawj Ntse
GNEE yog ib qho kev tshaj lij - nres kev daws teeb meem rau cov khoom lag luam steel ntawm Tuam Tshoj. Tus kheej-tsim Corten steel tsim thiab xeb thev naus laus zis tau mus txog lub ntiaj teb qhov nruab nrab cov txheej txheem.

 

Comprehensive Quality Service
Uas tsis tu ncua txaus siab cov kev xav tau sib txawv ntawm cov neeg siv khoom thoob plaws ntiaj teb hauv thaj chaw steel khoom siv. Pab neeg muag khoom tshaj lij, muab cov neeg siv khoom nrog thawj - cov kev pabcuam hauv chav kawm; kev yuav khoom nruj thiab pab neeg soj ntsuam zoo, ua tib zoo xaiv cov khoom zoo - zoo raw khoom; pab neeg tshawb fawb thiab kev tshaj lij los txhim kho kev tsim khoom thiab txo cov nqi rau cov neeg siv khoom; zoo heev tsim thiab ua pab neeg, ua tib zoo crafted thiab refined; intimate shipping logistics pab neeg tiv thaiv cov khoom thauj.

 

Pab neeg ua haujlwm zoo heev
GNEE nrog pab pawg kws tshaj lij, teb ceev ceev, lub sijhawm xa khoom luv, tus nqi sib tw zoo tshaj, kev pabcuam zoo tshaj.

 

Tus nqi sib tw
Peb siv zog los tswj tus nqi sib tw, muab cov neeg siv khoom siv suab thiab video uas xa tus nqi siab rau lawv cov peev txheej.

 

Pad Mounted Transformer

 

Cov khoom siv hluav taws xob twg nyob hauv Pad Mounted Transformer

High-voltage bushings:Cov no yog cov khoom siv insulated uas tso cai rau siab -voltage kev sib txuas ua rau lub transformer.


Transformer tub ntxhais:Qhov no yog lub hauv paus ntawm lub transformer uas muaj ib tug laminated hlau core tsim los muab ib txoj kev rau cov hlau nplaum flux.


Cua txias:Lub transformer windings yog tsim los ntawm insulated tooj liab conductors uas raug mob nyob ib ncig ntawm lub transformer core los muab qhov tsim nyog voltage transformation.


Coj mus rhaub changer:Qhov no yog ib qho cuab yeej kho tau uas tso cai rau lub tshuab hluav taws xob tso zis hluav taws xob hloov pauv los ntawm kev hloov cov lej hloov pauv hauv qhov hloov pauv winding.


Rwb thaiv tsev:Lub transformer yog ntim nrog ib tug haum insulating kua, xws li ntxhia roj, muab hluav taws xob rwb thaiv tsev thiab cua txias.


Cov cuab yeej tiv thaiv thiab tswj:Qhov no tej zaum yuav muaj xws li Circuit Court breakers, fuses, thiab relays uas tiv thaiv lub transformer thiab tis system los ntawm overloads thiab faults.


Tsawg-voltage bushings:Cov no yog cov khoom siv insulated uas tso cai rau qis-voltage kev sib txuas ua rau lub transformer.

 

Koj tuaj yeem pom dab tsi hauv Ib Daim Npav Mounted Transformer

Core:Lub ncoo mounted transformer tus tub ntxhais yog ua los ntawm cov ntawv laminated ntawm cov khoom sib nqus, xws li silicon steel.
Nws muab txoj hauv kev rau cov sib nqus flux thiab pab hloov hluav taws xob hluav taws xob los ntawm ib lub voj voog mus rau lwm qhov.


Cua txias:Pad mounted transformers nquag siv tooj liab thiab txhuas ua cov khoom siv hluav taws xob, thiab txhua tus muaj qhov zoo thiab yam uas yuav tsum nco ntsoov.


Rwb thaiv tsev:Rwb thaiv tsev feem ntau yog siv los cais cov windings thiab cov tub ntxhais kom tiv thaiv hluav taws xob arcing thiab luv circuits. Cov rwb thaiv tsev muaj ntau yam khoom siv, xws li ntawv, enamel, lossis resin.


Bushings:Lub ncoo mounted transformer lub bushing tsim hluav taws xob kev sib txuas ntawm cov khoom siv sab hauv thiab sab nrauv siab -voltage lossis low-voltage hluav taws xob system.
Bushings muab cov txheej txheem kom muaj kev nyab xeeb txav hluav taws xob tam sim no thiab qhov hluav taws xob mus rau hauv lossis tawm ntawm lub tshuab hluav taws xob ntxiv rau kev muab hluav taws xob rwb thaiv tsev thiab kev txhawb nqa txhua yam.


Coj mus rhaub Changers:Kais changers muab lub peev xwm los hloov lub transformer cov zis voltage los them rau cov input voltage los yog kom tau raws li cov kev cai load.

Pad Mounted Transformer

Yuav Ua Li Cas Kuv Tau Txais Cov Pad Transformer Npaj Rau Kev Txhim Kho

 

 

Kauj Ruam 1. Kev Npaj Qhov Chaw
Xyuas kom lub transformer ncoo muaj lub hauv paus zoo. Koj yuav tsum muab qhov chaw ruaj khov thiab tiaj tus uas yuav tsum muaj cov pob zeb lossis lwm yam khoom tsim nyog.
Xyuas kom lub chaw ua tau raws li qhov yuav tsum tau muaj hluav taws xob thiab kev nyab xeeb. Tshem tawm thaj tsam ntawm txhua qhov teeb meem, cov khib nyiab, lossis cov nroj tsuag uas tuaj yeem cuam tshuam nrog kev teeb tsa lossis nkag mus rau lub ncoo mounted transformers.

 

Kauj Ruam 2. Kev tsim kho pob zeb
Kev tsim kho ntawm lub pob zeb ua vaj tse rau kev teeb tsa ntawm cov pad mounted transformers feem ntau hu ua pob zeb pad construction.identify thiab khij lub luag haujlwm ntawm cov khoom siv hauv av uas twb muaj lawm, xws li kev sib txuas lus, dej, thiab roj kab.

 

Kauj ruam 3. Kev sib txuas hluav taws xob
Koom tes nrog lub tuam txhab hluav taws xob lossis tus neeg cog lus hluav taws xob los npaj kev sib txuas hluav taws xob rau lub ncoo mounted transformers. Qhov no tej zaum yuav muaj trenching los yog nteg underground cables los txuas lub transformer mus rau cov hluav taws xob daim phiaj los yog lub hwj chim qhov chaw.

 

Kauj Ruam 4. Tau txais daim ntawv tso cai thiab kev pom zoo
Tham nrog koj cov cai hauv zos kom pom tias muaj kev tso cai tsim nyog rau kev teeb tsa ntawm lub ncoo mounted transformer. Xyuas kom ua raws li tag nrho cov kev cai thiab cov cai.

 

Kauj Ruam 5. Transformer xa thiab tshuaj xyuas
Npaj rau kev xa khoom ntawm lub ncoo mounted transformer mus rau qhov chaw teeb tsa. Xyuas kom tseeb tias tag nrho cov khoom tsim nyog, khoom siv, thiab cov ntaub ntawv suav nrog.

 

Kauj Ruam 6. Nqa thiab tso chaw
Thaum lub transformer raug muab tso rau, ruaj khov thauj tog rau nkoj mus rau lub pob zeb pob zeb siv txoj kev pom zoo, xws li bolts lossis anchors. Tom ntej no yog txhawm rau txhim kho cov lus ceeb toom tsim nyog, qhov ntsuas hluav taws xob siab, thiab cov ntaub ntawv tiv tauj thaum muaj xwm ceev nyob ib puag ncig ntawm lub ncoo mounted transformer.

 

Kauj ruam 7. Cov ntaub ntawv thiab cov ntaub ntawv -Kev khaws cia
Khaws cov ntaub ntawv tseeb ntawm cov txheej txheem kev teeb tsa, suav nrog cov ntawv tso cai, kev tshuaj xyuas, thiab cov txiaj ntsig kev xeem. Khaws cov ntaub ntawv ntxaws ntxaws rau yav tom ntej siv thiab ua raws cov hom phiaj.

 

Cov lus qhia tseem ceeb rau kev nyob nyab xeeb ib puag ncig Pad-Mounted Transformers
 

Tswj Kev ncua deb:Thaum ua tau, tswj qhov kev ncua deb ntawm lub ncoo -mounted transformers. Cov lus qhia dav dav yog kom nyob deb tsawg kawg 10 feet ntawm cov khoom siv kom tsis txhob muaj kev phom sij. Lub thawv ntsuab muaj kev nyab xeeb hauv av, yog li nws muaj kev nyab xeeb rau qee zaus mow thiab txiav cov nroj tsuag uas sib sau nyob ib ncig ntawm lub hauv paus ntawm lub thawv.

 

Tsis muaj kev nkag mus tsis tau tso cai:Pad-mounted transformers yuav tsum tsuas yog nkag los ntawm cov neeg ua haujlwm raug cob qhia thiab tso cai. Tsis txhob sim qhib lossis cuam tshuam nrog cov cuab yeej tshwj tsis yog tias koj tsim nyog ua li ntawd.

 

Qhia txog qhov Qhib lossis Xauv Chav:Yog tias koj tuaj hla lub tshuab hluav taws xob uas muaj qhov qhib, puas, lossis tsis tuaj yeem kaw, thov hu rau Tampa Electric ntawm tus lej teev hauv qab no. Nco ntsoov tiv thaiv lwm tus los ntawm kev txav mus rau lub transformer kom txog thaum tus kws tshaj lij tuaj txog.
Tsis txhob pleev xim los yog npog. Cov xim ntsuab pab cov neeg ua haujlwm hluav taws xob txheeb xyuas lub tshuab hluav taws xob uas muaj qhov hluav taws xob nyob sab hauv thiab siv care.the xim tuaj yeem ua rau pom kev ceeb toom thiab ua rau lwm tus muaj kev pheej hmoo.

 

Khaws Kom Ncua Nroj Tsuag:Yog tias koj pom muaj cov roj xau nyob ib ncig ntawm lub ncoo -mounted transformer, khaws qhov deb thiab ceeb toom nws. Transformer roj yog flammable thiab tuaj yeem ua rau muaj hluav taws kub.

 

Tsis txhob tiv tauj dej:Tsis txhob cia dej nkag mus rau hauv ncoo -mounted transformers. Lub sijhawm tshuaj xyuas thiab kho koj cov nyom sprinklers. Dej siv hluav taws xob thiab tuaj yeem ua rau muaj hluav taws xob txaus ntshai.

 

Nyob Nrhav Thaum Muaj Xwm Ceev:Yog tias koj pom cov neeg ua haujlwm saib xyuas ua haujlwm ntawm lub ncoo -mounted transformer, hwm lawv qhov chaw ua haujlwm thiab tswj qhov kev ncua deb.

 

Tsis txhob khawb lossis cog ze ze:Cov xaim hauv av los ntawm lub tshuab hluav taws xob tuaj yeem ncav cuag txhua qhov kev taw qhia. Kev ntaus ib qho ntawm cov xov hlau no nrog lub duav tuaj yeem ua rau hluav taws xob.

 

Pad Mounted Transformer

 

Pad mount transformer kev nyab xeeb

Pad-mounted transformers, cov thawv siv hluav taws xob ntsuab loj uas pom nyob ib puag ncig hauv nroog, ua haujlwm rau lub hom phiaj ntawm kev txo qis hluav taws xob rau cov qauv hluav taws xob hauv tsev siv hluav taws xob, khoom siv hluav taws xob thiab teeb pom kev zoo. Cov transformers no tsis muaj kev tiv thaiv nyob rau hauv txoj kev overhead kab thiab substations. Txawm hais tias lawv yuav zoo li muaj kev nyab xeeb los siv ua cov rooj zaum ua haujlwm thiab kev nce toj siab, cov khoom siv hluav taws xob tseem tuaj yeem ua rau muaj kev pheej hmoo rau txhua tus neeg uas tuaj yeem ntsib nrog nws. Cov tswv cuab yuav tsum siv ceev faj thiab ua kom muaj kev nyab xeeb nyob deb.
Berkeley Electric crews kuj xav tau kev nyab xeeb rau kev kho thiab tu. Cov kev thaiv, xws li kev tsim kho vaj tse thiab laj kab, yuav tsum tau ceev nrooj ntawm cov khoom siv hluav taws xob. Txawm hais tias nws yuav ntxias "camouflage" transformers nrog kev tsim kho kom zoo nkauj, thov nco ntsoov cov neeg ua haujlwm koom tes yuav tsum muaj tsawg kawg yog 10- taw kev tshem tawm ntawm qhov qhib ntawm lub ncoo- mounted transformer thiab plaub-taw tom qab thiab ob sab ntawm lub tsev. Qhov kev ncua deb tso cai rau cov neeg ua haujlwm kom nyab xeeb siv cov cuab yeej xav tau los ua haujlwm nrog cov cuab yeej siv zog. Nws tseem ua kom cov neeg ua haujlwm muaj peev xwm txav mus los ntawm kev nyab xeeb yog tias muaj teeb meem tshwm sim.
Hauv ntau qhov kev faib tawm tshiab thiab kev tsim kho vaj tse nyob hauv ncoo- cov tshuab hloov pauv tau ntau dua - thiab nyob rau hauv ntau qhov chaw nyob ntawm cov neeg siv khoom. Cov transformers no txuas nrog thawj cov kab hluav taws xob siab, thiab cov kab nruab nrab tuaj yeem txuas ntxiv los ntawm kev hloov pauv hauv ntau cov lus qhia hauv av. Nco ntsoov qhov no ua ntej cog tsob ntoo lossis ntoo, teeb tsa cov laj kab, txhim kho cov tshuab txau lossis khawb qhov twg los ze ntawm lub tshuab hloov pauv.

 

Nyob qhov twg Pad -Mounted Transformers Siv

Qhov chaw nyob:Pad-mounted transformers feem ntau yog siv nyob rau hauv cov zej zog cov zej zog kom nqis siab - hluav taws xob hluav taws xob los ntawm cov hluav taws xob hluav taws xob mus rau qhov hluav taws xob qis tsim nyog rau kev siv hauv tsev. Lawv feem ntau yog ntsia rau ntawm cov pob zeb ua pob zeb lossis cov ntaub thaiv ze ntawm txoj kev lossis hauv lub tiaj nraum qaum tsev.


Commercial thiab Industrial Areas:Pad-mounted transformers kuj tseem muaj nyob rau hauv kev lag luam thiab kev lag luam thaj chaw uas lawv muab hluav taws xob faib rau cov tsev, factories, khw, thiab lwm yam lag luam. Cov transformers no pab muab hluav taws xob rau ntau yam hluav taws xob loads nyob rau hauv cov cheeb tsam no.


Nyob deb nroog thiab thaj chaw deb:Hauv cov chaw nyob deb nroog thiab thaj chaw deb, ncoo- cov tshuab hloov pauv feem ntau yog ua haujlwm los faib hluav taws xob rau cov tsev, ua liaj ua teb, thiab cov zej zog me. Lawv ua lub luag haujlwm tseem ceeb hauv kev txuas cov phiaj xwm hluav taws xob mus rau thaj chaw uas cov kab hluav taws xob siv hluav taws xob tsis tuaj yeem ua tau lossis raug nqi- zoo.


Underground Power Distribution:Pad-mounted transformers yog ib feem tseem ceeb ntawm underground power distribution systems. Hloov chaw siv cov kab hluav taws xob overhead, cov tshuab no cia siab rau cov kab faus kom thauj hluav taws xob. Pad-mounted transformers tau muab tso rau hauv kev sib txuas hauv av kom txo qis voltage thiab muab lub zog rau cov neeg siv khoom.

Pad Mounted Transformer

 

Pad mounted transformer txij nkawm
 
 
Kev tshuaj xyuas

Ua tsis tu ncua kev kuaj pom ntawm lub transformer thiab nws ib puag ncig, nrhiav cov cim ntawm kev puas tsuaj los yog hnav. Tshawb xyuas cov paib ntawm cov roj xau los yog kev puas tsuaj rau lub transformer sab nrauv thiab xyuas kom meej tias lub transformer tsis muaj khib nyiab.

 
Roj qib kuaj

Xyuas cov roj theem hauv lub transformer thiab sab saum toj yog tias tsim nyog. Nco ntsoov siv hom roj kom raug rau lub transformer

 
Ntxuav

Khaws lub transformer kom huv si thiab tsis muaj av thiab khib nyiab. Siv cov ntaub mos mos thiab cov tshuaj ntxuav me me los ntxuav lub tshuab hluav taws xob sab nrauv.

 
Kev kuaj hluav taws xob

Ua cov kev ntsuam xyuas hluav taws xob tsis tu ncua ntawm lub transformer kom paub meej tias nws ua haujlwm raug. Cov kev ntsuam xyuas no yuav tsum suav nrog kev tiv thaiv rwb thaiv tsev, kev hloov pauv, kev tiv thaiv winding, thiab kev ntsuas lub zog dielectric, nrog rau kev thauj khoom thiab tsis muaj -load poob kev sim.

 
Hloov cov khoom hnav lossis puas

Yog tias ib qho ntawm cov transformer pom tias hnav lossis puas thaum kuaj lossis kuaj, lawv yuav tsum tau hloov tam sim ntawd kom tsis txhob muaj kev puas tsuaj ntxiv.

 
Infrared kuaj

Siv lub koob yees duab infrared los xyuas qhov kub ntawm qhov chaw ntawm transformers thaum lawv nyob rau hauv load. Cov chaw kub kub tuaj yeem qhia txog cov teeb meem xws li kev sib txuas xoob, cov cua ntsawj puas, lossis kev puas tsuaj ntawm rwb thaiv tsev.

 

 

 
Peb lub Hoobkas

 

Cov khoom tau dhau SGS, intertek, CCC, CE thiab lwm yam ntawv pov thawj thoob ntiaj teb. Suab nrov, yooj yim installation, txuag hluav taws xob thiab emission txo, kev pab lub neej ntev, thiab lwm yam. Lub voj voog ntau lawm yog luv, yooj yim rau nruab, thiab xa khoom sai. Tam sim no, lub tuam txhab muaj ntau factories.Our pab neeg yog tsim los ntawm cov kws tshaj lij engineers. Peb sib zog ua kom xa koj raws sijhawm nyob rau hauv cov peev nyiaj siv hluav taws xob, thiab muab cov khoom zoo heev. Muab koj qhov kev paub dhau los.

 

202404181604086634e.jpg (1600×398)

 

 
Daim ntawv pov thawj

 

20240418141329319fb.jpg (921×500)

 

 
FAQ
 

Q: Yuav Ua Li Cas Kaw Ib Daim Npav -Mounted Transformer Ua Rau Ib Lub Tsev?

A: PadMounted Transformers tuaj yeem nyob ze li ob peb taw ntawm ib lub tsev, tab sis qhov ze ntawm lub transformer rau koj lub tsev, qhov phem dua nws yuav cuam tshuam rau koj lub zog hluav taws xob.
Yog tias koj nyob hauv 50 ko taw ntawm lub ncoo -mounted transformer, tej zaum koj yuav tau ua qee yam hluav taws xob ua ntej koj xa koj daim ntawv thov kev pom zoo.

Q: Puas muaj kev nyab xeeb los zaum ntawm ib lub ncoo -Mounted Transformer?

A: Yog. Nws muaj kev nyab xeeb los zaum ntawm ib sab ntawm lub ncoo -mounted transformer. Pad Mounted Transformers yog tsim los nrog kev nyab xeeb hauv siab.
Lawv kuj tau teeb tsa kom nyab xeeb kom txo qis kev pheej hmoo ntawm kev sib cuag los ntawm tib neeg lossis tsiaj txhu.

Q: Vim li cas PadMounted Transformers Painted Green?

A: Nws tsis yog qhov txawv ntawm cov khoom siv hluav taws xob uas yuav tsum tau pleev xim ntsuab rau kev nyab xeeb.
Thaum tib neeg ua haujlwm ntawm cov khoom siv hluav taws xob no, lawv xav tsis thoob los ntawm qhov muaj hluav taws xob nyob hauv chav tsev.
Cov xim ntsuab ua haujlwm ceeb toom rau cov neeg siv tias muaj qhov hluav taws xob nyob sab hauv.

Q: Dab tsi yog qhov yuav tsum tau ua rau lub ncoo mounted transformer?

A: 20 feet ntawm ntsug clearance yuav tsum tau siab tshaj tag nrho cov khoom siv . 5 ko taw ntawm txhua sab thiab 9 ko taw los ntawm 9 ko taw ntawm kev khiav hauj lwm ntawm cov cuab yeej yog qhov yuav tsum tau ntawm qhov chaw los ntawm ncoo- cov khoom siv.

Q: Dab tsi yog qhov kev nyab xeeb deb ntawm lub ncoo mounted transformer?

A: 10 feet
Khaws Kev ncua deb: Thaum ua tau, tswj qhov kev ncua deb ntawm lub ncoo -mounted transformers. Cov lus qhia dav dav yog kom nyob deb tsawg kawg 10 feet ntawm cov khoom siv kom tsis txhob muaj kev phom sij.

Q: Muaj pes tsawg lub tsev tuaj yeem ua lub ncoo mounted transformer kov?

A: Qhov no ib theem pad mount transformer muaj nyob rau hauv cov chaw nyob lossis chaw lag luam me. Lawv hloov hluav taws xob los ntawm 7200 volts rau 120/240 volts. Ib qho kev hloov pauv loj npaum li no pub rau 10-15 lub tsev lossis ib lossis ntau dua kev lag luam me.

Q: Puas tuaj yeem pad-mounted transformers txav tau?

A: Thaum siv lub crane raug txwv, lub ncoo -mounted transformer tuaj yeem txav tau siv lub tshuab dov. Thaum lub sij hawm txav, lub transformer yuav tsum tau khaws cia nyob rau hauv ib tug ntsug lub xeev thiab tsiv horizontally.

Q: Puas muaj kev nyab xeeb los zaum ntawm lub ncoo -mounted transformer?

A: Thaum lawv tau tsim kom muaj kev nyab xeeb, cov xwm txheej uas yuav ua rau lub tshuab hluav taws xob tsis zoo tsis tuaj yeem txiav txim siab tag nrho. Nws yog qhov zoo dua kom koj nyob deb thiab qhia koj cov menyuam kom ua ib yam. Tshawb nrhiav thiab ua raws li cov ntawv ceeb toom ntawm lub ncoo- cov tshuab hloov pauv thiab tag nrho lwm yam khoom siv hluav taws xob.

Q: Puas yog lub ncoo-mounted transformers muaj kev nyab xeeb kov?

A: Tsis txhob kov, nce lossis ua si ntawm lub ncoo -mounted transformer. Tsis txhob muab ntiv tes, sticks los yog lwm yam khoom los ntawm cov kab nrib pleb hauv lub transformer.

Q: Lub hom phiaj ntawm lub ncoo -mounted transformer yog dab tsi?

A: Padmount transformers yog siv rau hauv av hluav taws xob xa hluav taws xob cov kab ntawm cov kev pabcuam poob qis kom nqis qis dua qhov tseem ceeb ntawm txoj kab mus rau qhov qis dua theem nrab voltage muab rau cov neeg siv khoom siv hluav taws xob. Ib lub tshuab hloov pauv tuaj yeem ua haujlwm rau ib lub tsev loj lossis ntau lub tsev.

Q: Koj muab lub ncoo -mounted transformer nyob qhov twg?

A: Padmounted transformers feem ntau yog ntsuab / daj lub thawv hlau / txee nyob ib sab ntawm txoj kev taug kev lossis txoj kev. Cov chav nyob feem ntau yog hais txog 0.6 m (2 feet) siab thiab muaj ib lub qhov rooj. Ob peb chav nyob loj dua thiab muaj ob lub qhov rooj. faus hauv qab thiab txuas mus rau lub transformer yog nyob rau hauv hluav taws xob cables.

Q: Qhov tsawg kawg nkaus clearance nyob ib ncig ntawm lub ncoo -mounted transformers?

A: Qhov tsawg kawg nkaus ua hauj lwm clearance nyob ib ncig ntawm pad mount transformers yog 8 ko taw mus rau sab laug, 10 ko taw nyob rau hauv pem hauv ntej, thiab 3 ko taw qab thiab rau sab xis ntawm lub ncoo mount transformer. Yog hais tias metering nyob rau hauv lub ncoo mount transformer, qhov tsawg kawg nkaus clearance mus rau sab xis yog 5 ko taw. Saib daim duab saum toj no.

Q: Yuav ua li cas deb ntawm phab ntsa transformer?

A: Tsis yog- Cov Transformers ventilated yuav tsum yog tsawg kawg yog 3 ntiv tes los ntawm ib qho kev cuam tshuam ntawm txhua sab thiab sab saum toj. Newer Energy Efficient (EX Type) yuav tsum tau . 5" los ntawm lub nraub qaum thiab sab mus rau txhua qhov kev cuam tshuam. Epoxy resin puv Transformers tuaj yeem ntsia ncaj qha rau ntawm phab ntsa, tab sis yuav tsum tau 12 ntiv tes ntawm ob sab, sab saum toj thiab hauv qab.

Q: Muaj pes tsawg volts yog lub ncoo -mounted transformer?

A: Pad-mounted transformers tuaj nyob rau hauv txhua qhov ntau thiab tsawg, tab sis muaj qee yam uas koj yuav tsum paub tam sim ntawd thaum twg koj pom lawv: Muaj ob qhov hluav taws xob siab (txog 23,000 volts) thiab theem nrab voltage (120/240/480 volts) sab hauv. Lawv yog hlau. Tag nrho cov hluav taws xob los thiab mus rau hauv av.

Q: Dab tsi yog siv los txuas cables rau lub ncoo mounted transformer?

A: Lub tshuab hloov pauv tuaj yeem muab lub zog rau lub tsev loj lossis ntau lub tsev. Pad transformers raug ntsuas ntawm 15 thiab 5000 KVA thiab feem ntau suav nrog ua - hauv fuses thiab keyboards. Lub ntsiab fais fab cable tuaj yeem txuas nrog lub luj tshib txuas.

Q: Dab tsi yog qhov txawv ntawm lub ncoo mounted thiab hauv av mounted transformers?

A: Pad-mounted transformers, tseem hu ua av transformers, muaj nuj nqi li transformers rau underground fais fab kab. Ib yam li lawv cov nyiaj siv ua haujlwm, lawv txo qhov voltage ntawm hluav taws xob mus rau qib tsim nyog rau kev siv hauv cov qauv.

Q: Muaj pes tsawg lub tsev tuaj yeem ua lub ncoo -mounted transformer kov?

A: Qhov no ib theem pad mount transformer muaj nyob rau hauv cov chaw nyob lossis chaw lag luam me. Lawv hloov hluav taws xob los ntawm 7200 volts rau 120/240 volts. Ib qho kev hloov pauv loj npaum li no pub rau 10-15 lub tsev lossis ib lossis ntau dua kev lag luam me.

Q: Dab tsi yog pad-mounted transformers ua los ntawm?

A: Cov ntaub ntawv nyob hauv tsev -mounted transformers yog hauv av-mounted transformers uas txhais tau tias muab hluav taws xob rau ntau lub tsev. Tsis tas li ntawd, lawv yog cov xaim hluav taws xob xa hluav taws xob kaw hauv lub txee steel ntsia ntawm lub pob zeb ua vaj tse.

Q: Hom roj twg yog siv rau hauv ncoo -mounted transformers?

A: Cov roj ntxhia lossis cov kua dej ester ntuj tuaj yeem siv tau. Mineral roj yog tus qauv rau ntau tus neeg siv khoom thiab yog qhov zoo rau feem ntau daim ntawv thov. Peb kuj tuaj yeem siv cov kua dej ntuj ester, uas feem ntau tau los ntawm cov roj zaub thiab biodegradable - ua rau nws yog qhov kev xaiv zoo tshaj plaws rau cov uas xav txo lawv cov kev cuam tshuam ib puag ncig.

Q: Cov xim dab tsi yog pad-mounted transformers?

A: Muaj tsib qhov sib txawv IEEE specifications rau cov transformers thiab enclosures lag luam. Cov xim siv feem ntau rau ntu no yog ANSI 70 Grey (siab gloss) thiab Pad Mount Green (semi-gloss).

Henan GNEE Electric Co., Ltd. yog ib qho ntawm cov kev tshaj lij pad mounted transformer manufacturers thiab lwm tus neeg nyob hauv Suav teb, kuj txhawb kev pabcuam customized. Txais tos mus yuav cov khoom siv hluav taws xob ruaj khov mounted transformer hauv Tshuag ntawm no thiab tau txais pricelist los ntawm peb lub hoobkas. Peb kuj txais customized txiav txim.

Xa kev nug