YBM seriesprefabricated substationyog ib qho khoom siv sib cog lus suav nrog HV switchgear, tis transformer, Switchgear, hluav taws xob hluav taws xob metrological ntaus ntawv thiab cov khoom siv hluav taws xob reactive, tag nrho cov khoom siv tau ntim rau hauv ib lossis ob peb lub cubic units, uas yog xaim los ntawm cov txheej txheem hluav taws xob kom raug. Nws yog tsim rau peb theem AC system nrog ntsuas voltage ntawm 10/0.4kV. Nws tuaj yeem siv los txais thiab xa hluav taws xob hluav taws xob rau cov chaw tsim khoom, mines, roj av, chaw nres nkoj, tshav dav hlau, nroog pej xeem cov tsev, txoj kev loj, cov chaw hauv av thiab lwm qhov chaw.
Lub prefabricated substation yog featured technically los ntawm tag nrho cov apparatus muaj zog, compact ntim, zoo tsos, muaj kev nyab xeeb thiab txhim khu kev qha kev khiav hauj lwm, yooj yim txij nkawm, zoo tsos, yooj yim txav, sib sib zog nqus load center, siv sij hawm luv luv, thiab pov tseg thiab lwm yam zoo.
Parameter Technical Data
| Yam khoom | Chav tsev | HV khoom siv hluav taws xob | Hloov pauv | LV khoom siv hluav taws xob |
| Rated voltage | kV ua | 10 | 10/0.4 | 0.4 |
| Rated tam sim no | A | 630 | 100-2500 | |
| Rated zaus | Hz | 50 | 50 | 50 |
| Rated peev | kVA ua | 100-1250 | ||
| Rated thermal stability tam sim no | kA | 20/4S | 30/1S | |
| Rated dynamic stability tam sim no (peak) | kA | 50 | 63 | |
| Rated kaw luv-circuit tam sim no (peak) | kA | 50 | 15-30 | |
| Rated tawg luv Circuit Court tam sim no | kA | 31.5 (Fuse) | ||
| Rated tawg load tam sim no | A | 630 | ||
| 1 min fais fab zaus withstand voltage | kV ua | Nruab nrab ntawm theem, mus rau lub ntiaj teb 42, qhib kev sib cuag 48 | 35/28 (5 feeb) | 20/2.5 |
| Lightning impulse withstand voltage | kV ua | Nruab nrab ntawm theem, mus rau lub ntiaj teb 75, qhib kev sib cuag 85 | 75 | |
| Shell tiv thaiv chav kawm | IP23 | IP23 | IP23 | |
| Lub suab nrov | dB | 630 | Roj transformer<55 Dry transformer<65 | |
| Loops No. | 2 | 4~30 | ||
| Tsawg voltage sab max static var compensator | kvar | 300 |

EU Hom Prefabricated Compact Substation Nta
- Lub txee muaj ob lub qauv: ib qho yog skeleton welding, uas weld skeleton nrog steel ua ntej, ces rub riveting los yog weld vaj huam sib luag. Lwm qhov yog skeleton los ua ke; steel phaj yog tsim los ntawm kev khoov thiab ua rau saum npoo. Thaum kawg, steel phaj yog sib sau ua ke los ntawm kev sib txuas bolt. Lub cev pob txha sib dhos yog tus cwj pwm los ntawm kev nthuav dav ntawm cov khoom siv hluav taws xob tsawg, uas tuaj yeem muab tso nrog tsis pub tsawg tshaj 6 panels ntawm qis voltage switchgear, nrog 812 loops. Lub substation prefabricated tuaj yeem tsim los ua haujlwm hauv tsev thiab chav ua haujlwm.
- lt muaj zoo rwb thaiv tsev kub thiab cua ntsuas ntsuas. Ob txheej txheej txheej yog saws nyob rau hauv lub txee, thiab cov khoom siv hluav taws xob rwb thaiv tsev kuj tau teem rau hauv interlayer, uas zoo txo qhov kub thiab txias los ntawm tshav ntuj. Lub transformer compartment yog teem rau ntawm. Nyob rau sab saum toj ntawm lub rooj vag tsis siv neeg qhov cua ntxuam, sab sauv yog muab nrog lub kaw lus, tuaj yeem lav tias lub tshuab hloov pauv tuaj yeem ua haujlwm nyab xeeb ntawm tag nrho cov khoom hauv lub caij kub.
GNEE Workshop

Cim npe nrov: eu hom prefabricated compact substation, Tuam Tshoj eu hom prefabricated compact substation manufacturers, lwm tus neeg, Hoobkas