10000V Mine Transformer

10000V Mine Transformer

Qhuav- hom mine transformer yog cov khoom siv hluav taws xob tshwj xeeb tsim tshwj xeeb rau ib puag ncig tshwj xeeb xws li mines, nrog tawg- pov thawj, hluav taws kub, dej noo- pov thawj thiab lwm yam ntxwv, thiab tuaj yeem ua haujlwm ruaj khov hauv ib puag ncig hnyav.
Xa kev nug
Tsham tam sim no

Muaj lus nug? GNEE cov neeg muag khoom muaj nyob rau hauv kev sib tham tam sim no

Xa E-mail:sales@gneeelectric.com

Tel:+8615824687445

Henan GNEE Electric Co., Ltd. yog ib qho ntawm feem txhim khu kev qha manufacturers thiab lwm tus neeg ntawm 10000v mine transformer nyob rau hauv Suav teb. Yog hais tias koj yuav mus yuav customized 10000v mine transformer ua nyob rau hauv Suav teb, txais tos kom tau txais cov lus hais los ntawm peb lub hoobkas. Cov khoom zoo thiab tus nqi tsim nyog muaj.

 

Taw qhia ntawm 10000V mine transformer


 

GNEE TRANSFORMER muab 10000V mine transformer.

Mine qhuav- hom transformer tshwj xeeb yog siv rau cov khoom siv hluav taws xob thiab cov khoom xa tawm hauv cov mines, haum rau cov mines uas tsis muaj phom sij xws li methane thiab cov hmoov av. Nws lub hom phiaj tseem ceeb yog muab lub zog rau hauv av hauv nruab nrab substation, qhov chaw nres tsheb hauv av, lub hauv paus cua nkag thiab lwm qhov chaw.

 

Daim ntawv thov thiab tej yam kev mob ntawm kev siv

  • Qhov siab tsis tshaj 2000m;
  • ambient kub tsis siab tshaj +40℃;
  • Cov huab cua txheeb ze tsis tshaj 95% (ntawm +25 degree);
  • Tsis muaj zog pob vibration thiab inclination ntawm lub dav hlau ntsug Tsawg dua los yog sib npaug rau 15℃ib puag ncig;
  • Tsis muaj gases thiab vapors txaus los corrode hlau thiab rhuav tshem rwb thaiv tsev:
  • Ib qho chaw tsis muaj dej ntws.

 

10000V mine transformer

Rated peev

(kVA)

Tsis muaj load

tam sim no (%)

Luv -circuit

impedance (%)

Tsis muaj load

poob (W)

Thaum load

poob (W)

50 2.5 4 350 680
100 2.5 500 1050
200 2 850 1800
315 1.8 1200 2500
400 1.8 1350 3000
500 1.5 1600 3500
630 1.5 1800 4100
800 1.2 2100 5100
1000 1.2 4.5 2350 6100
1250 1.0 2800 7400
1600 1.0 5 3450 8500
2000 0.7 4050 9700
2500 0.7 5.5 4700 10800
3150 0.7 5500 12800
4000 0.7 6 6300 15000
5000 0.6 7300 17600
6300 0.6 8500 20000

 

tuam txhabprofile


 

GNEE TRANSFORMER muaj peev xwm tsim tau zoo thiab pab pawg ua lag luam tau zoo.

 

Peb cov khoom siv hluav taws xob muaj xws li 500kV, 400kV, 330kV, 220kV, thiab 110kV ultra-high voltage transformers, ntau yam qhuav- hom transformers / roj immersed transformers / amorphous alloy transformers ntawm 35kV thiab hauv qab no, tshiab zog transformers, thiab substations, prefabricated

 

Export series: ib zaug -theem transformer, peb-theem transformer, cylindrical transformer, cais transformer, tswj transformer, voltage regulator thiab lwm yam khoom, Thiab ntau yam specifications ntawm tshwj xeeb transformers xws li grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, hluav taws xob rectifier transformers, thiab lwm yam.

 

GNEE TRANSFORMER tau ua tiav dhau ISO9001, ISO14001, ISO45001, SA8000 daim ntawv pov thawj system. Tib lub sijhawm, 10kV thiab 35KV theem faib transformers thiab lub thawv hom substations tau txais interna - tional Electrotechnical Commission IEC ntawv pov thawj, US UL ntawv pov thawj, German TUV ntawv pov thawj, EU CE ntawv pov thawj, Dutch KEMA ntawv pov thawj, thiab GOST ntawv pov thawj. Peb cov khoom muag npog thoob ntiaj teb kev lag luam, suav nrog 72 lub teb chaws thiab cheeb tsam xws li Tebchaws Meskas, Europe, Canada, Mexico, thiab lwm yam.

 

transformer Rhiav khoom siv zaub


Transformer Test equipment
Cov khoom siv kuaj
Transformer Test equipment2
Cov khoom siv kuaj

 

Oil transformation workshop
Roj transformation Rhiav
Dry transformation workshop
Qhuav transformation Rhiav

 

Transformer Intelligent automatic bending machine
Intelligent automatic dabtsi yog khoov tshuab
Transformer Cnc punch press
Cnc punch xovxwm

 

Transformer Intelligent laser cutting machine
Ntse laser txiav tshuab
Transformer Welding robot
Vuam neeg hlau

 

Transformer Fully automatic laminating unit
Fully automatic laminating unit
Transformer Fully automatic laminating unit2
Fully automatic laminating unit

 

Transformer Wire winding unit
Hlau winding unit
Transformer Wire winding unit2
Hlau winding unit
Transformer Wire winding unit3
Hlau winding unit
 
 
 
 
 
 

hom transformer los ntawm GNEE


 

500kV roj-immersed ib zaug-theem ob-winding unexcited voltage regulating fais fab transformer

500kV roj-immersed peb-theem ob-winding unexcited voltage regulating fais fab transformer
330kV roj-immersed peb-theem ob-winding unexcited voltage regulating hwj chim transformer
330kV roj-immersed peb-theem peb-winding unexcited voltage regulating hwj chim transformer
220kV roj-immersed peb-theem ob-winding unexcited voltage regulating fais fab transformer
220kV roj-immersed peb-theem peb-winding unexcited voltage regulating fais fab transformer
220kV roj-immersed peb-theem ob-winding ntawm-load voltage regulating fais fab transformer
220kV roj-immersed peb-theem peb-winding ntawm-load voltage regulating fais fab transformer
110kV roj-immersed peb-theem ob-winding unexcited voltage regulating hwj chim transformer
110kV roj-immersed peb-theem peb-winding unexcited voltage regulating fais fab transformer
110kV roj-immersed peb-theem ob-winding ntawm-load voltage regulating fais fab transformer
110kV roj-immersed peb-theem peb-winding ntawm-load voltage regulating fais fab transformer
66kV roj-immersed peb-theem ob-winding unexcited voltage regulating hwj chim transformer
66kV roj-immersed peb-theem ob-winding ntawm-load voltage regulating fais fab transformer
35kV roj-immersed peb-theem ob-winding unexcited voltage regulating hwj chim transformer
35kV roj-immersed peb-theem ob-winding ntawm-load voltage regulating fais fab transformer
10kV roj-immersed peb-theem ob-winding unexcited voltage regulating hwj chim transformer
10kV roj-immersed peb-theem ob-winding ntawm-load voltage regulating fais fab transformer
S(B)H15(21~25)-M kaw amorphous alloy fais fab transformer
SCB peb -seem core transformer
35kV qhuav-hom tsis-excitation voltage regulating fais fab transformer
35kV qhuav- hom ntawm -load voltage regulating fais fab transformer
35kV qhuav-hom peb-theem ob- winding transformer rau photovoltaic, cua zog thiab lub zog cia ntawm lub zog tshiab lub zog tsim hluav taws xob sab yam tsis muaj kev tswj xyuas hluav taws xob
20kV qhuav- hom tsis yog -excitation voltage regulating faib transformer
10kV qhuav-hom peb-theem ob-winding tsis yog-excitation voltage regulating faib transformer
10kV qhuav-hom peb- theem ob- winding transformer rau photovoltaic, cua zog thiab lub zog cia ntawm lub zog tshiab lub zog tsim hluav taws xob
SC(B)H15(17 ~ 19) amorphous alloy qhuav hom transformer
SG(B)12 ~ 18 tsis yog-encapsulated H-chav qhuav hom transformer
CSD marine transformer
SGB ​​peb-seem core transformer
Tshiab zog transformer
35kV roj-immersed peb-theem ob-winding tsis- zoo siab voltage kev cai tshiab zog tiam sab rau photovoltaic, cua zog, lub zog cia transformers
10kV roj-immersed peb-theem ob-winding tsis yog- zoo siab voltage kev cai tshiab zog tiam sab rau photovoltaic, cua zog, lub zog cia transformers
Prefabricated chav tsev substation
Integrated inverter thiab kauj ruam -up converter
10000V mine transformer
6000V mine transformer
faus transformer
Theem -hloov rectifier transformer
Hluav taws xob rauv transformer
Grounding transformer
QSG/SG peb -theem qhuav rho tawm transformer
Peb-phase ncoo-mounted transformer
Tib -phase ncoo-mounted transformer
Tib -theem ncej-mounted transformer

Tau txais Transformer Order specification

GNEE TransformerOrder specification

Thaum xaiv peb lub tuam txhab cov khoom, thov muab cov ntaub ntawv hauv qab no los pab koj zoo dua.

Kev thov

Kev thov:

Xov tooj txoj kev:

Fax:

Project tus thawj coj:

Xov tooj txoj kev:

Xa ntawv:

Transformer hom xaiv

□ Qhuav transformer

{□SC(B) Epoxy resin □SC(B) Tsis yog-encapsulated}

□American Box(ZGS)

{□Terminal type(-Z-) □Ring network type(-H-)}

□European Box hloov (YBM){□ hloov qhuav □ hloov roj}

□ Roj-immersed transformer{□ Tag Nrho (-M-) □Oil-cov kabmob hauv ncoo}

□Amorphous alloy transformer{□Dry amorphous □ Roj amorphous}

□ Tshwj xeeb transformer {Rectifier, Rauv, Mine, Etc}

Transformer pib xaiv cov ntaub ntawv

Lub teb chaws siv:

 

Phase naj npawb:

□Peb-theem(S conventional) □ Monophase □Lwm yam()

Ntau zaus:

□ 50Hz (paub) □ 60Hz □ Lwm yam ()

Transformer roj:

□ # 25 (tseem ceeb) □ # 45 (qhov kub thiab txias qis dua -25 degree)

Rated peev:

□( )kVA Cov xwm txheej siv □ Sab nraum zoov □ hom sab hauv tsev

Qhov siab:

□ Tsawg dua 1000m (paub) □ 1000-2000m □ 3000m 以上 tshaj

Rated voltage (High voltage)

□6kV □10kV □20kV □35kV □66kV 110kV □220kV □Lwm yam ()

Rated voltage (tsis tshua muaj siab)

□0.4kV □0.66kV 10kV □10.5kV □35kV □其他 ( )

Pab pawg sib txuas

□Dyn11(conventional) □Yyn0 □YNd11 □li0(Tib-theem) □Lwm yam()

Impedance (%):

□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □ Lwm yam ( )

Voltage tswj hom

□ Kev tswj hluav taws xob yam tsis muaj kev txhawb siab (paub) □Ntawm -load voltage regulation(Z)

Voltage tswj ntau yam

□ ± 2 * 2.5% □ ± 5% □ ± 3 * 2.5% □ Lwm yam ()

Transformer accessory xaiv

□Ntxuam □Kev tswj qhov kub thiab txias{□ Feem ntau □Nrog 485 lub computer interface}

□ Cov ntaub ntawv qhuav{ □ Ordinary steel ntawv □Aluminium alloy » Stainless hlau}

□ Kev tiv thaiv qib ntawm cov ntaub ntawv qhuav ( □IP20 (Conventional) □IP( )}

□ Cov ntaub ntawv qhuav qhov siab yuav tsum tau{□Tsis muaj □Yuav tsum tau muaj[ ]}

□ Cable tawm hom ntawm lub plhaub hloov pauv qhuav

{□ Up-thiab-tawm □ Nce toj-thiab- nqis □ nqis-in/down-tawm □ nqis-in/UP- tawm □ nqis-hauv / nqes- tawm □ nqis {{10} sab □{10} sab hauv/{10} Txoj cai- tawm]}

Nco tseg:

1. (Kev hloov pauv qhuav s 100kVA transformer tsis suav nrog cov kiv cua, xws li kiv cua, yuav tsum tau them

2. (Cov roj hloov<630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee)

Lwm cov kev cai tshwj xeeb (cov nqi ntxiv hauv qab no)

Qhuav transformer

□ Plhaub thiab hauv qab phaj{ □ Ib txwm □ kaw tag nrho} □ Hloov mus los □ Sib nqus lo

□ Zero sequence transformer □ tooj liab bar rau lub txee tsis muaj hluav taws xob

□ Tiv thaiv mesh □ Teeb pom kev zoo □ 100kVA lossis tsawg dua Ntxuam □ Shock absorber

Roj-immersed transformer

□No.45 roj rau cov uas tsis yog- qhov chaw kub tsis tshua muaj □ Tsim hom rau ntawm -load voltage regulator

□ 400kVA thiab qis dua qhov hluav taws xob hluav taws xob qis OABC theem nrog cov khoom siv hluav taws xob

□ 630kVA lossis qis dua yuav tsum tau tswj qhov kub thiab txias

□ 800kVA lossis qis dua qhov hluav taws xob qis hluav taws xob theem 0 yuav tsum tau xaim hluav taws xob

□ 630kVA thiab hauv qab no yuav tsum tau nruab nrog roj relay

 

GNEE TRANSFORMER Industrial Layout


 

Asia: Tuam Tshoj, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Nyab Laj, Mongolia, Nyiv, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Qaib ntxhw, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan

 

Teb chaws Africa: Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa

 

North America: Aruba, Panama, Dominican koom pheej, Costa Rica, Honduras, Caribbean cheeb tsam, Canada, United States, Mexico, El Salvador, Guatemala, Jamaica

 

Teb chaws Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Ltalis, United Kingdom

 

South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile

 

Middle East: Cov cheeb tsam Middle East

 

Oceania: Australia, Papua New Guinea. Fiji

 

Cim npe nrov: 10000v mine transformer, Tuam Tshoj 10000v mine transformer manufacturers, lwm tus neeg, Hoobkas

Xa kev nug