Nruab nrab Voltage Pad Mount Transformer
Puas muaj lus nug? Gnee Cov Neeg Sawv Cev Muag Khoom muaj nyob rau cov kev sib tham tam sim no
Xa e-mail:sales@gneeelectric.com
Tel:+8615824687445
Lub ncoo mount nruab nrab voltage transformer yog ib hom kev faib hluav taws xob hauv av rau kev siv sab nraum zoov lossis hauv av. Pad mount fais fab kev faib cov chav nyob yog kaw (tsis muaj cov kab hluav taws xob los yog cov kab hluav taws xob), rau kev xa mus ze rau cov haujlwm siab thiab cov chaw pej xeem. Qhov no feature kuj tso cai rau cov chaw nres tsheb yuav tsum tau ntsia tsis muaj fencing thiab tsawg heev cabling, uas ua rau cov nqi qis dua thiab txhim khu kev qha fais fab kev sib txuas.
|
Yam khoom |
Chav tsev |
Cov ntaub ntawv |
|
|
HV |
Rated Zaus |
Hz |
50 |
|
Rated voltage |
kV ua |
6 10 35 |
|
|
Max ua haujlwm voltage |
kV ua |
6.9 11.5 40.5 |
|
|
Fais fab zaus withstand voltage Ntawm ncej rau lub ntiaj teb / lsolating nrug |
kV ua |
32/36 42/48 95/118 |
|
|
xob laim impulse withstand voltage Ntawm ncej rau lub ntiaj teb / cais nrug |
kV ua |
60/70 75/85 185/215 |
|
|
Rated tam sim no |
A |
400 630 |
|
|
Rated luv-lub sij hawm tiv taus tam sim no |
kA |
12.5(2S) 16(2S) 20(2S) |
|
|
Rated ncov tiv taus tam sim no |
kA |
32.5 40 50 |
|
|
LV |
Rated voltage |
V |
380 200 |
|
Rated tam sim no ntawm lub ntsiab Circuit Court |
A |
100-3200 |
|
|
Rated luv-lub sij hawm tiv taus tam sim no |
kA |
15 30 50 |
|
|
Rated ncov tiv taus tam sim no |
kA |
30 63 110 |
|
|
Ceg Circuit Court |
A |
10 - 800 |
|
|
Tus naj npawb ntawm ceg Circuit Court |
/ |
1 - 12 |
|
|
Kev them nyiaj muaj peev xwm |
kVAR ua |
0 - 360 |
|
|
Hloov pauv |
Rated peev |
kVA ua |
50-2000 |
|
Short-circuit impedance |
% |
4 6 |
|
|
Scope ntawm ceg kev sib txuas |
/ |
±2×2.5% ±5% |
|
|
Kev sib txuas pab pawg cim |
/ |
Yyn0 Dyn11 |
|

Cov txiaj ntsig ntawm Medium Voltage Padmount Transformer
- Nruab nrab voltagePadmount Transformersyog qhov zoo heev thaum xav tau kev pabcuam hauv av. Feem ntau koj yuav pom lawv tom qab khw, khw noj mov lossis hauv chaw ua si.
- Peb cov transformers muab cov nqi tsim nyog rau koj cov kev xav tau ntawm lub zog. GNEE cov khoom lag luam ntawm cov khoom siv hluav taws xob tshiab tshaj li tag nrho cov qauv kev siv hluav taws xob hauv teb chaws - suav nrog NEMA, ANSI thiab IEEE - ntxiv rau kev pom zoo ENERGY STAR thiab Department of Energy (DOE) kev ntsuam xyuas, yog li koj tuaj yeem xa ntau lub zog ntawm tus nqi qis.
- Peb kuj tuaj yeem tsim ib chav padmount rau spec. Txawm hais tias koj xav tau ib chav tsev lossis 100 units, koj tuaj yeem tau txais txiaj ntsig los ntawm kev hloov kho kom haum rau txhua daim ntawv thov, los ntawm tsev kho mob, tsev kawm qib siab thiab chaw ua haujlwm rau cov chaw muag khoom thiab chaw tsim khoom.
Nruab nrab voltage Padmount Transformer Applications
Cov chaw niaj hnub no, los ntawm cov tsev kawm ntawv mus rau cov chaw tsim khoom, yuav tsum tau muab lub zog rau ntau yam kev siv thev naus laus zis - suav nrog huab-npaj sensors thiab cov cuab yeej ntse. Ntawm ELSCO, peb muaj kev paub dhau los hauv kev tsim thiab tsim cov khoom siv hluav taws xob kom tau raws li cov chaw xav tau. Peb tau ua haujlwm nrog cov neeg siv khoom los muab kev npaj ua tiav, kev cai lub zog daws teeb meem rau:
- Nruam txheej txheem manufacturers
- Just-in-Time Industrial Suppliers
- Universities thiab Colleges
- Tsev Kho Mob thiab Chaw Kho Mob
- Industrial Utility tuam txhab uas muag
- Kho qhov chaw
- Cov neeg cog lus hluav taws xob
- Cov Tsev Siv Hluav Taws Xob
Ntim & shipping


Cim npe nrov: Tuam Tshoj nruab nrab voltage ncoo mount transformer, Tuam Tshoj nruab nrab voltage ncoo mount transformer manufacturers, lwm tus neeg, Hoobkas