Cov roj-immersed transformer yog transformer qhov twg cov tub ntxhais thiab windings yog submerged nyob rau hauv insulating roj nyob rau hauv lub steel tank. Cov roj no muab qhov tseem ceeb ua kom txias, rwb thaiv tsev, thiab tiv thaiv noo noo rau cov khoom. Nws ua haujlwm los ntawm kev siv convection los ncig cov roj, uas nqa cov cua sov tawm ntawm lub hauv paus thiab windings rau radiators rau dissipation.

 

Cov roj ntau npaum li cas hauv 100 kVA transformer?

Rau ib tug ncej-mounted transformer, cov roj hnyav yog 94kg, rau ib zaug xwb -theem ncoo-mounted transformer, cov roj yog 141kg.

100 KVA 3 pahse Transformer Specification

100 KVA Transformer Daim Ntawv Qhia

100 KVA Transformer muaj peev xwm

100 kVA

Txuj

IEC60076

Txias hom

ONAN

Rated Voltage

HV11000V-LV415/240V

Theem

3 faaj

Ntau zaus

50 HZ

Vector Group

Dyn 11

100 KVA Transformer Load Capacity Hauv KW

80 KW TSI

100 KVA Transformer Puv Load Tam Sim No

HV5.25A/LV139.12A

100 KVA Transformer impedance

4%

100 KVA Transformer Dimensions

1000 * 800 * 750mm

100 KVA Transformer Copper Nyhav

200 kg

Roj Peev Xwm Ntawm 100 KVA Transformer

160 kg

100 KVA Transformer Nyhav

6 15kg

100 KVA Copper Transformer Nqe

USD1 * 00.00 / SET

 

100 KVA Transformer Paub meej

100 KVA Transformer Details

100 KVA Transformer Nameplate

100 KVA Transformer Nameplate

1. Muaj pes tsawg amps yog 100 KVA transformer?

HV5.25A/LV139.12A

 

2.Qhov 100 KVA transformer hnyav npaum li cas?

Roj Luj: 160 KG

Qhov hnyav tag nrho tsis suav nrog roj: 455 KG

Tag nrho qhov hnyav suav nrog roj: 615 KG

Qhov hnyav tag nrho nrog cov khoom xa tuaj: 650 KG

 

3.Cov roj ntau npaum li cas hauv 100 KVA transformer?

160 KG

 

4. Muaj pes tsawg lub tsev tuaj yeem muab 100 KVA transformer?

Tus naj npawb ntawm lub tsev 100 KVA transformer tuaj yeem muab tau nyob ntawm ntau yam xws li qhov loj thiab lub zog ntsuas ntawm txhua lub tsev, qhov deb ntawm lub transformer thiab lub tsev, thiab qhov hluav taws xob load ntawm txhua lub tsev. Feem ntau, 100 KVA transformer tuaj yeem muab lub zog rau nruab nrab ntawm 30 thiab 50 qhov nruab nrab -cov tsev loj.

 

5.Tus nqi ntawm 100 KVA transformer yog dab tsi?

USD1 * 00.00 / SET

 

6.Qhov loj npaum li cas yog 100kVA transformer?

100kVA transformer qhov loj me txawv txawv nyob ntawm hom, tab sis qhov ntev feem ntau yog li ntawm 1150 × 760 × 1360.mm rau qee qhov peb -phase units mus txog 1000 × 700 × 700mm rau ib zaug -theem ncej-mounted qauv. Qhov hnyav kuj txawv, los ntawm kwv yees li 500-720 kg rau qhuav lossis ncej-mounted hom mus rau 680 kg lossis ntau dua rau qee cov roj ntim.

Qhov loj thiab qhov hnyav variations

 

Hom Qhov Loj (L x W x H) Qhov hnyav (kwv yees)
Peb-Theem Roj-Immered 1150 x 760 x 1360 mm mm 6 80kg
Tib -Phase Ncej-Mounted 1000 x 700 hli (cylindrical) mm (cylindrical) Nws txawv, nyob ntawm tus qauv tshwj xeeb thiab mounting
Ib leeg-Phase Pad-Mounted 740 x 940 x 910 mm mm Nws txawv, nyob ntawm tus qauv tshwj xeeb thiab mounting
Hom qhuav 850x650x1150 mm mm 500 kg

 

7.

Lub peev xwm thauj khoom ntawm 100 kVA transformer hauv kW yog dab tsi?

80 kWm

100 KVA transformer load peev hauv kW

 

8.Puas muaj pes tsawg kw yog 100 kVA 3 theem?

Cov qauv kev hloov pauv kVA rau kW yog:

100 kVA x 0.8 =80 kW ib.

1, transformer tso zis fais fab yog qhov pom tseeb, thiab lub zog ua haujlwm (KW) kev sib raug zoo yog:pom meej zog=active zog x fais fab tuag. 2, nrog rau qhov nruab nrab lub zog ntawm 0.8 xam, 100 KVA transformer muaj peev xwm muab tau (100 KVA × 0.8) 80 KW active zog rau lub load.

roj-immersed transformer Specifications

Hermetically Sealed Siab nrog Mineral roj hom

1. Specifications (Technical Data yuav raug hloov tsis tau ceeb toom.)

 

1-1. 22kV - 400/230V & 24kV - 416/240V

Yam khoom Muaj peev xwm Tsis muaj load Load poob (75oC) Impedance Qhov Loj (mm) Tag nrho qhov hnyav Roj
kVA ua Watt Watt % Qhov siab Ntev Dav kg Liter
1 50 160 950 4 1,100 1,000 700 500 135
2 100 250 1,550 4 1,250 1,050 750 750 200
3 160 360 2,100 4 1,300 1,150 750 990 250
4 250 500 2,950 4 1,350 1,200 750 1300 300
5 315 800 3,900 4 1,400 1,400 800 1300 350
6 400 960 4,600 4 1,400 1,500 850 1550 380
7 500 1,150 5,500 4 1,500 1,550 900 1750 430
8 630 1,350 6,500 4 1,550 1,600 850 2,150 450
9 800 1,600 11,000 6 1,600 1,800 1,100 2,500 650
10 1,000 1,950 13,500 6 1,750 1,900 1,100 3,200 700
11 1,250 2,300 16,400 6 1,850 2,000 1,150 4,000 850
12 1,500 2,800 19,800 6 1,950 2,100 1,250 4,150 1,150
13 2,000 3,250 24,000 6 2,050 2,250 1,350 5,650 1,450
14 2,500 3,500 28,500 6 2,150 2,450 1,450 6,450 1,750

 

1-2. 33kV - 400/230V

Yam khoom Muaj peev xwm Tsis muaj load Load poob (75oC) Impedance Qhov Loj (mm) Tag nrho qhov hnyav Roj
kVA ua Watt Watt % Qhov siab Ntev Dav kg Liter
1 50 170 950 4 1,300 1,000 700 550 165
2 100 260 1,550 4 1,400 1,050 750 800 230
3 160 370 2,100 4 1,450 1,150 750 990 280
4 250 520 2,950 4 1,500 1,200 750 1450 350
5 315 850 3,900 4 1,550 1,350 800 1450 400
6 400 1000 4,600 4 1,550 1,450 850 1700 450
7 500 1,200 5,500 4 1,650 1,500 900 1900 500
8 630 1,400 6,500 4 1,700 1,650 850 2,300 550
9 800 1,700 11,000 6 1,750 1,850 1,100 2,650 700
10 1,000 2,000 13,500 6 1,900 1,950 1,100 3,350 750
11 1,250 2,350 16,400 6 2,000 2,000 1,150 4,150 900
12 1,500 2,850 19,800 6 2,100 2,100 1,250 4,300 1,200
13 2,000 3,300 24,000 6 2,200 2,250 1,350 5,800 1,450
14 2,500 3,800 28,500 6 2,350 2,450 1,450 6,600 1,750

Distribution Transformer Outline

info-1-1

Kev faib tawm Transformer

info-1-1

 

2. Cov khoom siv (Standard & Option)

Yam khoom   kVA ua 50 100 160 250 315 400 500 630 800 1000 1250 1500 2000 2500
1 Bushings   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
2 Arcing horn   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
3 Off load tap changer   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4 Lub ntiaj teb terminal   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
5 Lifting lug   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
6 Nqa qhov muag   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
7 Lub log   ○ ○ ○ ○ ○ ○ ○ ○ ○ ● ● ● ● ●
8 Daim ntawv npe   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
9 Roj ntws   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
10 Thermometer hnab tshos   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
11 Marshaling lub thawv   ○ ○ ○ ○ ○ ○ ○ ○ ○ ● ● ● ● ●
12 Cable lub thawv   ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
13 P'ry davhlau ya nyob twg connector Pad hom ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Clamp hom ● ● ● ● ● ● ● ● ● ● ● ● ● ●
14 Lub davhlau ya nyob twg connector Pad hom ● ● ● ● ● ● ○ ○ ○ ○ ○ ○ ○ ○
Clamp hom ○ ○ ○ ○ ○ ○ ● ● ● ● ● ● ● ●
15 Roj qib ntsuas W/O hu rau ● ● ● ● ● ● ● ● ● ● ● ● ● ●
16 Qhov ntsuas kub W/O hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
2 hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ● ● ● ● ●
17 WDG Temp.indicator 2 hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
18 Cov cuab yeej siv siab W/O hu rau ● ● ● ● ● ● ● ● ● ● ● ● ● ●
1 hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Accessaries List
● Standard Accessaries
○ Xaiv Accessaries

 

3. Cov lus hais

Fuji Tusco tseg txoj cai rau kev hloov pauv ntawm cov ntaub ntawv no, ntawm no.

Distribution transformers yog tsim los rau kev siv dav siv nyob rau hauv qhov kub thiab txias siab tshaj 40℃ntawm qhov kub thiab txias nce 60℃(sab saum toj roj) / 65℃(winding), uas yuav raug tsim thiab sim ua raws li qhov tseeb IEC tus qauv.

 

Qhib hom nrog Conservator Tank (Mineral Oil)

 

1. Specifications (Technical Data yuav raug hloov tsis tau ceeb toom.)

 

1-1. Qhib hom nrog Conservator Tank 22kV - 400/230V & 24kV - 416/240V

Yam khoom Muaj peev xwm Tsis muaj load Load poob (75oC) Impedance Qhov Loj (mm) Tag nrho qhov hnyav Roj
kVA ua Watt Watt % Qhov siab Ntev Dav kg Liter
1 50 160 950 4 1,250 1,300 850 650 150
2 100 250 1,550 4 1,350 1,300 850 750 200
3 160 360 2,100 4 1,450 1,400 850 950 250
4 250 500 2,950 4 1,550 1,500 850 1200 320
5 315 800 3,900 4 1,600 1,550 850 1250 350
6 400 960 4,600 4 1,650 1,600 900 1550 380
7 500 1,150 5,500 4 1,700 1,700 950 1800 450
8 630 1,350 6,500 4 1,750 1,800 950 2,100 600
9 800 1,600 11,000 6 1,850 1,900 1,050 2,650 650
10 1,000 1,950 13,500 6 2,050 2,050 1,150 3,200 700
11 1,250 2,300 16,400 6 2,100 2,250 1,200 4,000 900
12 1,500 2,800 19,800 6 2,250 2,250 1,350 4,200 1,100
13 2,000 3,250 24,000 6 2,350 2,300 1,400 5,500 1,200
14 2,500 3,500 28,500 6 2,500 2,500 1,550 6,500 1,800

 

1-2. Qhib hom nrog Conservator Tank 33kV - 400/230V

Yam khoom Muaj peev xwm Tsis muaj load Load poob (75oC) Impedance Qhov Loj (mm) Tag nrho qhov hnyav Roj
kVA ua Watt Watt % Qhov siab Ntev Dav kg Liter
1 50 170 950 4 1,450 1,400 900 700 200
2 100 260 1,550 4 1,550 1,400 900 800 250
3 160 370 2,100 4 1,650 1,500 900 1,000 300
4 250 520 2,950 4 1,750 1,600 900 1250 350
5 315 850 3,900 4 1,750 1,650 900 1350 400
6 400 1000 4,600 4 1,800 1,700 950 1650 450
7 500 1,200 5,500 4 1,850 1,800 1000 1900 500
8 630 1,400 6,500 4 1,900 1,900 1,000 2,200 650
9 800 1,700 11,000 6 2,000 2,000 1,100 2,750 700
10 1,000 2,000 13,500 6 2,200 2,150 1,200 3,500 750
11 1,250 2,350 16,400 6 2,250 2,350 1,250 4,500 950
12 1,500 2,850 19,800 6 2,400 2,350 1,400 4,800 1,150
13 2,000 3,300 24,000 6 2,500 2,400 1,450 6,200 1,250
14 2,500 3,800 28,500 6 2,650 2,600 1,600 7,200 1,850

 

Distribution Transformer Outline

info-1-1

Kev faib tawm Transformer

info-1-1

 

2. Cov khoom siv (Standard & Option)

Yam khoom   kVA ua 50 100 160 250 315 400 500 630 800 1000 1250 1500 2000 2500
1 Bushings   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
2 Arcing horn   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
3 Off load tap changer   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
4 Dehydrating breather puv nrog
silica gel
  ● ● ● ● ● ● ● ● ● ● ● ● ● ●
5 Lub ntiaj teb terminal   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
6 Lifting lug   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
7 Nqa qhov muag   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
8 Lub log   ○ ○ ○ ○ ○ ○ ○ ○ ○ ● ● ● ● ●
9 Daim ntawv npe   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
10 Roj ntws   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
11 Thermometer hnab tshos   ● ● ● ● ● ● ● ● ● ● ● ● ● ●
12 Marshaling lub thawv   ○ ○ ○ ○ ○ ○ ○ ○ ○ ● ● ● ● ●
13 Cable lub thawv   ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
14 P'ry davhlau ya nyob twg connector Pad hom ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Clamp hom ● ● ● ● ● ● ● ● ● ● ● ● ● ●
15 Lub davhlau ya nyob twg connector Pad hom ● ● ● ● ● ● ○ ○ ○ ○ ○ ○ ○ ○
Clamp hom ○ ○ ○ ○ ○ ○ ● ● ● ● ● ● ● ●
16 Roj qib ntsuas W/O hu rau ● ● ● ● ● ● ● ● ● ● ● ● ● ●
17 Qhov ntsuas kub W/O hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
2 hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ● ● ● ● ●
18 WDG Temp.indicator 2 hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
19 Buchholz relay 2 hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ● ● ● ● ●
19 Cov cuab yeej siv siab W/O hu rau ● ● ● ● ● ● ● ● ● ● ● ● ● ●
1 hu rau ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Accessaries List
● Standard Accessaries
○ Xaiv Accessaries

 

3. Cov lus hais

Fuji Tusco tseg txoj cai rau kev hloov pauv ntawm cov ntaub ntawv no, ntawm no.

Distribution transformers yog tsim los rau kev siv dav siv nyob rau hauv qhov kub thiab txias siab tshaj 40℃ntawm qhov kub thiab txias nce 60℃(sab saum toj roj) / 65℃(winding), uas yuav raug tsim thiab sim ua raws li qhov tseeb IEC tus qauv.

Xa kev nug