2000 kVA Transformer Tam sim no Peev Xwm thiab Voltage Conversion: Daim Ntawv Qhia Ua tiav

May 11, 2026

Tso lus

2000 kVA Transformer yog dab tsi?

Lub 2000 kVA transformer yog peb -theem fais fab transformer nrog lub zog pom tseeb ntawm 2000 kilovolt-amperes, uas sib npaug 2 MVA. Nws yog feem ntau siv los txo qis nruab nrab voltage, xws li 11 kV lossis 33 kV, kom tsis tshua muaj hluav taws xob, xws li 400 V lossis 690 V, rau cov neeg siv khoom lag luam thiab kev lag luam. Tib lub tshuab kuj tuaj yeem nce lub tshuab hluav taws xob hluav taws xob rau daim phiaj xa tawm hauv cov nroj tsuag hluav taws xob tauj dua tshiab. Nws cov qauv tsim ua raws li kev ntsuas, ntsuas kub thiab txias qhov yuav tsum tau teev tseg hauv IEC 60076-1 thiab IEC 60076-2, thiab nws yog npaj rau kev ua haujlwm tas mus li ntawm cov khoom ntsuas nyob rau hauv qhov ntsuas kub nce siab.

Yuav ua li cas xam lub peev xwm nqa tam sim no

Lub peev xwm nqa tam sim no ntawm 2000 kVA transformer txhais qhov siab tshaj plaws nruam thauj khoom tam sim no ntawm txhua qhov winding yam tsis pub dhau lub thermal txwv. Vim tias nws tsis yog ib tus nqi ruaj khov, nws yuav tsum tau muab xam rau qhov tseeb kev khiav hauj lwm voltage ntawm txhua sab. Rau peb lub -theem transformer, cov kab tam sim no tau muab los ntawm cov qauv tsim nyog:

I (A)=S (kVA) × 1000 / (√3 × V (V))

Cov lus hauv qab no siv cov qauv no rau cov kev teeb tsa hluav taws xob feem ntau tau teev tseg rau 2000 kVA transformer.

Qib voltage Full Load Line Tam sim no Hom Sab
33kv ua 35 A Thawj high voltage
11kv ua 105 A Thawj high voltage
0 ,69kv 1673 A Secondary low voltage
0,4kv ua 2887 A Secondary low voltage

Qhov qis-voltage sab ntawm 400 V xav tau busbars, kev sib txuas thiab kev sib txuas tau zoo tshaj 3000 A, thiab winding conductor cross-sections raug xaiv nrog qhov ceev tam sim no uas tiv thaiv cov chaw kub hauv zos, feem ntau 2 txog 3 A ib square millimeter rau tooj liab.

Thermal Limits thiab Overload Performance

Lub peev xwm nqa tau tam sim no yog tswj hwm los ntawm cov chav kawm rwb thaiv tsev thiab cov txheej txheem txias. Rau cov roj-immersed unit nrog ONAN txias, qhov nruab nrab cua kub nce yog txwv rau 65 K thiab qhov kub ntawm - qhov kub thiab txias nce mus txog 78 K, raws li IEC 60076-2 thiab phau ntawv qhia kev thauj khoom IEC 60076-7. Lub sijhawm luv luv overloads ntawm li 10 mus rau 20 feem pua ​​​​ntawm cov ntsuas tam sim no tuaj yeem zam tau rau lub sijhawm txwv yam tsis muaj qhov tseem ceeb ntawm lub neej rwb thaiv tsev, muab cov roj thiab cov cua kub tswj xyuas. Cov chav nyob nrog kev yuam kom txias, xws li ONAF, txhawb nqa lub sijhawm luv luv, uas ua rau lawv tsim nyog rau kev hloov pauv cov ntaub ntawv hauv cov tuam tsev lag luam thiab cov chaw khaws ntaub ntawv.

Voltage Conversion Principles

Kev hloov hluav taws xob nyob rau hauv 2000 kVA transformer ua raws li txoj cai hloov pauv: qhov induced voltage nyob rau hauv txhua lub winding yog proportional rau tus naj npawb ntawm lem, thaum lub hwj chim pauv yuav luag tas li sib nrug los ntawm kev poob. Lub impedance voltage, feem ntau nyob rau hauv thaj tsam ntawm 4.5 mus rau 7 feem pua ​​​​rau qhov kev ntsuam xyuas no, txiav txim siab qhov hluav taws xob poob qis hauv kev thauj khoom thiab txwv qhov luv luv -circuit tam sim no. Txhawm rau kom cov zis hluav taws xob ruaj khov thaum thawj qhov hluav taws xob hloov pauv, kais hloov pauv tau haum rau qhov siab -voltage winding, feem ntau nrog ntau yam ± 2 × 2.5 feem pua ​​lossis ± 5 feem pua; tawm-cov hloov pauv hloov pauv hloov pauv hloov pauv nrog lub zog de- zog, thaum nyob rau -load kais hloov pauv tso cai hloov pauv yam tsis cuam tshuam cov khoom siv.

Technical Parameters ntawm Ib Hom 2000 kVA Transformer

Parameter Specification
Rated peev 2000 kVA ua
Thawj qhov voltage 11 kV lossis 33 kV, customizable
Secondary voltage 0.4 kV lossis 0.69 kV, customizable
Ntau zaus 50 Hz lossis 60 Hz
Phase Peb -theem
Txoj kev txias ONAN, ONAF lossis OFAF
Cov khoom siv winding Tooj los yog txhuas
Rwb thaiv tsev chav kawm Class A rau cov roj- raus dej
Impedance voltage 4.5 rau 7%.
Kub nce 65 K nruab nrab winding, 78 K kub qhov chaw
Tapping ntau ± 2 × 2.5 feem pua ​​​​tawm -circuit lossis ntawm -load
Vector pawg Dyn11, Yyn0 los yog raws li xav tau
Cov qauv IEC 60076, IEEE C57.12.00

Daim ntawv thov thiab Load Considerations

Lub 2000 kVA transformer haum rau nruab nrab- cov nroj tsuag kev lag luam, chaw lag luam, tsev kho mob thiab tsev kawm ntawv network, kev ua haujlwm tsuas thiab cov khoom siv hluav taws xob tauj dua tshiab. Thaum qhia txog chav tsev, ntsuas tag nrho cov khoom txuas nrog hauv kW, lub zog ua haujlwm, qhov sib txawv thiab qhov kev cia siab ntawm kev loj hlob tshaj li tsib mus rau kaum xyoo, thiab khaws cov peev txheej ntawm 10 txog 20 feem pua. Kev tiv thaiv yuav tsum muaj xws li overcurrent thiab lub ntiaj teb txhaum relays, lub ntsuas kub ntawm cov roj nrog lub tswb thiab kev sib cuag mus txawv tebchaws, thiab Buchholz relay rau siab ceev thiab roj tsub zuj zuj hauv cov kua - puv units. Kev ntsuam xyuas niaj hnub ua ntej kev ua haujlwm suav nrog kev hloov pauv, kev ua haujlwm winding, rwb thaiv tsev tsis kam thiab impedance voltage ntsuas raws li IEC 60076-1.

FAQ

Q:Yuav ua li cas yog lub load tam sim no ntawm 2000 kVA transformer ntawm 11 kV?

A:Kwv yees li 105 A, xam raws li 2000 × 1000 muab faib los ntawm cov khoom ntawm √3 thiab 11000 V.

Q:Dab tsi yog qhov tag nrho load tam sim no ntawm 400 V sab?

A:Kwv yees li ntawm 2887 A, uas yog vim li cas qhov qis -voltage kev sib txuas, busbars thiab cov cuab yeej tiv thaiv yuav tsum tau ntsuas zoo tshaj 3000 A.

Q:ONAN txias txhais li cas?

A:Nws txhais tau hais tias roj ntuj huab cua: cov roj circulates los ntawm ntuj convection thiab dissipates tshav kub los ntawm lub tank thiab radiators tsis muaj twj los yog kiv cua, raws li tau hais tseg nyob rau hauv IEC 60076-2.

Q:Vim li cas qhov impedance voltage tseem ceeb?

A:Lub impedance voltage, feem ntau 4.5 mus rau 7 feem pua, txwv qhov luv luv -circuit tam sim no thiab txiav txim siab qhov voltage poob hauv load; qis impedance muab cov kev cai voltage zoo dua tab sis ua rau muaj kev ntxhov siab thaum muaj teeb meem.

Q:Lub 2000 kVA transformer puas tuaj yeem overloaded?

A:luv- lub sij hawm overloads ntawm 10 mus rau 20 feem pua ​​​​yog ua tau yam tsis muaj kev puas tsuaj loj ntawm rwb thaiv tsev lub neej, tab sis cov roj thiab cua kub yuav tsum tau saib xyuas; Kev ruaj ntseg overload txo cov rwb thaiv tsev lub neej exponentially raws li daim ntawv qhia kev thauj khoom IEC 60076-7.

Q:Cov ntaub ntawv dab tsi yuav tsum tau muab thaum qhia txog 2000 kVA transformer?

A:Peev xwm, thawj thiab theem nrab voltages, zaus, txias txoj kev, vector pawg, impedance, winding khoom, tapping ntau, installation qhov chaw thiab cov qauv siv ntawm lub teb chaws lo lus uas peb.

Xa kev nug