Yuav ua li cas kom tsis txhob muaj roj leakage thiab overheating ntawm 1500kVA Roj -Immersed Transformer

Jun 23, 2026

Tso lus

Cov1500kVA roj-raug faib transformer yog cov khoom siv hluav taws xob tseem ceeb rau cov chaw tsim khoom lag luam, chaw ua lag luam, chaw ua haujlwm hauv nroog thiab cov kab ntau lawm. Vim nws muaj peev xwm loj, ntev - lub sij hawm tag nrho - load lag luam thiab siab thermal stress, ob qho kev txhaum tshwm sim ntau zaus hauv kev ua haujlwm tiag tiag: tank roj to thiab winding overheating, uas ncaj qha ua rau daim phiaj tsis txaus siab, tsis tau npaj tseg, kev nplua ib puag ncig thiab kev tiv thaiv kev laus acceleration.

 

GNEE Hluav taws xob ua ke ua ke siab -permeability grain- taw qhia silicon steel, 100% tooj liab windings, thiab advanced transformer manufacturing technology kom xa cov txhim khu kev qha thiab lub zog-ntau 1500kVA roj-immersed transformers. Featuring tag nrho cov kaw corrugated tank qauv, optimized txias kev ua tau zoo, thiab nruj lub Hoobkas kuaj, GNEE transformers yog tsim los txo cov kev pheej hmoo ntawm roj to thiab overheating thaum ua kom lub neej ntev kev pab cuam thiab ruaj khov nyob rau hauv industrial, hluav taws xob, thiab kev lag luam fais fab tshuab thoob ntiaj teb.

 

1500kVA Transformer Oil Leakage 

Yog vim li cas 1500kVA Transformers muaj ntau dua rau roj Leakage & Overheating

Piv nrog rau cov me me 500/1000kVA units, 1500kVA qauv ua haujlwm nyob rau hauv cov txheej txheem ntau dua thiab thermal stress, ua rau nws muaj kev pheej hmoo siab rau kev xau thiab overheating.

 

1. Load yam ntxwv

– These transformers typically run at 80‑100% rated load year‑round, with summer peaks reaching 110‑120% overload. Sustained high temperatures accelerate seal and insulation aging. Three‑phase load imbalance (neutral current >25%) ntxiv ua rau lub hauv paus cua sov overheating, ib qho teeb meem tsis tshua tseem ceeb nyob rau hauv me me transformers.

 

2. Tsim kev tsis txaus

- Cov tso tsheb hlau luam loj dua thiab cov welds ntev dua xav tau kev tsim khoom zoo dua, tab sis cov tuam txhab txiav nqi feem ntau txo cov cua txias, siv cov hlau nyias nyias, thiab hla kev sim tsis tu ncua. Tus qauv ONAN txias yog qhov txaus txaus; Thaum ambient siab tshaj 40 degree, thermal margin yuav txaus ntshai heev nyias.

 

Cov Lus Qhia Tshwj Xeeb:Hauv peb qhov kev paub dhau los, 1500kVA transformers sawv cev rau qhov muaj peev xwm tseem ceeb uas qhov kev ntxhov siab thermal nce ntau piv nrog 500kVA thiab 1000kVA units, thaum ntau tus neeg siv tseem ua haujlwm rau lawv yam tsis tau yuam kom txias. Yog li ntawd, cov roj to thiab overheating kev tsis txaus siab feem ntau qhia nyob rau hauv no muaj peev xwm ntu tshaj nyob rau hauv me me transformers.

 

1500kVA Transformer

 

Technical Root ua rau 1500kVA Transformer Roj Leakage

 

  • Kev tsim khoom:Kev vuam tsis zoo (pinholes, tsis muaj fusion) ntawm cov tso tsheb hlau luam loj thiab cov flange tsis sib xws cuam tshuam kev sib khi thawj zaug. Cov hlau nyias thiab cov txheej tsis zoo ua rau corrosion perforation hauv 2-3 xyoos sab nraum zoov.
  • Cov ntsaws ruaj ruaj:Ordinary NBR gaskets (tsuas yog 100-120 degree) tawv thiab tawg tom qab 1-2 xyoos nyob rau hauv cov roj kub kub ntawm 80-95 degree, ua rau tsis tshua muaj kev foob.
  • Site tej yam kev mob:Lub hauv paus kev daws teeb meem lim lub tank; overfilling nce lub siab sab hauv; rov qab thermal cycling accelerates qaug zog ntawm welds thiab seals.

 

1500kVA Transformer Oil Leakage 

Technical Root ua rau 1500kVA Transformer Overheating

 

  • Internal defects:Aluminium windings (resistivity 1.68 × tooj liab) ua rau kom tooj liab poob, thaum qis-qib silicon steel nce hlau poob; incorrect impedance tsim ntxiv aggravates cua sov.
  • Cua txias system:Cov hluav taws xob tsis zoo, qhov ntsuas kub tsis zoo, thiab cov qauv tsim roj tsis zoo txo ​​cov cua sov - ONAN cua txias feem ntau ua pov thawj marginal saum 40℃ambient.
  • Cov yam ntxwv ua haujlwm: Long‑term overload, inadequate ventilation, three‑phase imbalance >10%, thiab cov roj degraded (moisture / impurities) tag nrho ua rau qhov kub thiab txias uas siab tshaj IEC txwv, ob npaug ntawm rwb thaiv tsev laus rau txhua txhua 6℃nce thiab nws thiaj li ua rau muaj kev poob lossis hluav taws.

Overheating In 1500kVA Transformers

 

Tswv yim Engineering:Lub transformer ua hauj lwm tsis tu ncua ntawm 90% load nyob rau hauv ib tug 40℃ambient ib puag ncig yuav muaj siab winding kub tshaj ib tug transformer khiav ntawm 100% load nyob rau hauv ib tug 25℃ib puag ncig. Ambient tej yam kev mob yuav tsum nco ntsoov muab xam ua ke nrog loading theem thaum ntsuam xyuas overheating txaus ntshai.

 

Yuav ua li cas kom tsis txhob muaj roj leakage thiab overheating nyob rau hauv 1500kVA Transformers - Core Measures

 

Tiv thaiv kom tsis txhob muaj roj:

  • Welding thiab sealing:Siv ib qho kev khoov lossis cov txheej txheem vuam tsis siv neeg rau lub tank; ua qhov kev ntsuam xyuas penetrant ntawm qhov tseem ceeb welds. Ua ntej xa khoom, ua qhov ntsuas qhov ntsuas qhov zoo ntawm lub tshuab nqus tsev siab tshaj lossis sib npaug ntawm 0.05 MPa rau ntau dua lossis sib npaug rau 24 teev kom tshem tawm cov pinholes thiab lub tshuab tshuab.
  • Txhim kho foob:Qhia meej FKM (Viton) gaskets rau tag nrho cov flanges thiab kev sib txuas, nrog rau qhov kub thiab txias tsis tu ncua saum 200 degree, zam lub hardening thiab tawg ntawm NBR seals tom qab 1-2 xyoos hauv qab 80-95℃roj kub.
  • Tank tiv thaiv corrosion:Siv tshuaj tua-blasting ua raws li epoxy zinc-nplua nuj primer thiab polyurethane topcoat, ua tiav qib tiv thaiv corrosion Ntau dua lossis sib npaug C3 kom tiv thaiv xeb tsis pub dhau 2-3 xyoos nyob rau sab nraum zoov.
  • Kev tsim kho kom zoo:Txais yuav ib lub thawv ntim tag nrho corrugated tank tsim, tshem tawm tus neeg saib xyuas thiab tso cai rau cov corrugated fins rau nws tus kheej hloov mus rau thermal expansion thiab contraction, txo cov ntsiab lus xau los ntawm qhov chaw.

 

Tiv thaiv overheating:

  • Cov khoom siv winding:Teem caij 100% ntshiab tooj liab windings, tshem tawm txhuas hloov; optimize lub electromagnetic tsim kom cov load poob raws li IEC txwv (piv txwv li, Tsawg dua los yog sib npaug rau 12 500 W ntawm 75 degree), yog li txo cov tooj liab poob thiab hluav taws kub ntawm qhov chaw.
  • Core khoom:Siv high-permeability grain-oriented silicon steel kom txo tsis-load poob thiab cov tub ntxhais cua sov, zam qhov kub thiab txias tsis tu ncua tshwm sim los ntawm qib qis cov tub ntxhais hlau.
  • Cooling margin: For summer ambient temperatures >35℃lossis txuas ntxiv ua haujlwm puv sijhawm, xaiv rau ONAF (them cua) txias nrog cov kiv cua uas pib ua haujlwm thaum roj kub txog 55 degree, txhim kho cov cua sov. Ntxiv rau qhov loj ntawm lub tshuab hluav taws xob kom ntseeg tau tias cov roj kub siab tshaj qhov siab dua los yog sib npaug li 60 K.
  • Kev ntsuas kub:Nruab PT100 platinum tiv thaiv sensors rau lub sijhawm saib xyuas ntawm cov roj kub sab saum toj thiab simulated winding hotspot kub, nrog lub tswb kub kub thiab tiv thaiv kev tiv thaiv kom tsis txhob muaj qhov txawv txav.
  • Kev ua haujlwm & kho:Tsis txhob ncua sij hawm ntau dhau (tshaj li 110% tam sim no), tswj peb-theem load tshuav (tsis sib npaug<10%), regularly test oil quality (moisture, dielectric loss, breakdown voltage), and replace oil periodically to ensure cooling and insulation performance do not degrade.

 

Overheating In 1500kVA Transformers

 

Field Observation:Raws li cov ntaub ntawv kev pabcuam hauv cheeb tsam, kev sib kis ntawm lub tshuab hluav taws xob yog ib qho uas tsis pom zoo ua rau overheating. Hauv cov chaw muaj plua plav, lub tshuab hluav taws xob hnyav hnyav tuaj yeem txo qhov ua kom txias thiab ua rau lub tswb ceeb toom tsis tsim nyog.

 

Vim li cas thiaj xaiv GNEE Electric?

 

GNEE Electric, nrog nws cov kev lag luam tag nrho cov saw ntsug ntsug kev sib koom ua ke muaj peev xwm, muab cov khoom siv hluav taws xob uas ua tau raws li cov qauv kev tswj hwm tag nrho hauv qab no:

 

  • Kev tsim khoom:Peb cov khoom muaj 100% ntshiab tooj liab windings thiab FKM (Viton) seals. Txhua lub tank raug kuaj xyuas qhov zoo ntawm lub tshuab nqus tsev siab ntawm ntau dua lossis sib npaug ntawm 0.05 MPa rau 24 teev, nrog 100% kev tshuaj xyuas ntawm cov welds tseem ceeb. Txhua chav ua tau raws li IEC qhov poob thiab qhov ntsuas kub nce siab, thiab tau txais cov ntawv qhia ua tiav hom.
  • Kev teeb tsa:Peb muab cov txheej txheem kev teeb tsa tsim nyog suav nrog kev txhim kho lub hauv paus, cov roj ntim kom zoo (nrog rau qhov chaw nthuav dav txaus), thiab muaj qhov cua txaus, tshem tawm cov kev pheej hmoo los ntawm kev ua haujlwm tsis raug ntawm qhov chaw.
  • Kev ua haujlwm:Peb cov transformers siv high-permeability grain-oriented silicon steel thiab optimized electromagnetic tsim rau tsawg load poob. Ib qho kev xaiv ONAF yuam-cua txias system tuaj yeem ua haujlwm tau thaum lub caij ntuj sov siab lossis lub luag haujlwm ua haujlwm ntev, txo cov roj kub ntawm 10-15℃thiab txuas ntxiv lub neej rwb thaiv tsev.
  • Ceeb toom ntxov:PT100 sensors yog tus qauv rau kev saib xyuas lub sijhawm ntawm cov roj kub thiab cua kub cua kub, nrog lub tswb kub kub thiab kev tiv thaiv kev mus ncig. Peb kuj muab cov lus pom zoo rau kev ntsuas roj zoo thiab kev cob qhia kev saib xyuas, pab koj tshawb xyuas thiab hais txog qhov me me thiab qhov kub tsis zoo tshwm sim thaum ntxov, ua ntej qhov kev ua txhaum loj tuaj.

 

GNEE Electric Solution:

Peb 1500kVA roj-immersed tis transformers yog tsim nrog tag nrho hauv tsev ntsug kev koom ua ke los ntawm silicon steel rau cov khoom tiav, nruj me ntsis siv tag nrho cov kev ntsuas saum toj no - 100% tooj liab windings, FKM ntsaws ruaj ruaj, lub tshuab nqus tsev vacuum kuaj, xaiv ONAF txias, thiab ua tiav IEC hom ntawv xeem. Tsim tshwj xeeb rau kev ua haujlwm tas mus li kev ua haujlwm tas mus li, lawv txo qis kev pheej hmoo ntawm cov roj to thiab overheating, ua kom lub neej ua haujlwm ntev, thiab txo cov nqi khiav lag luam thiab kev saib xyuas. Rau cov ncauj lus kom ntxaws specifications los yog customized daws, thov hu rau peb.

Thov Ib Daim Quote

 

1500kVA oil‑immersed distribution transformer

 

Installation & Maintenance Essentials rau 1500kVA Transformers

 

Kev teeb tsa

  • Foundation:Cov kabmob muaj peev xwm Ntau dua lossis sib npaug ntawm 10 t / m²; levelness Tsawg dua los yog sib npaug li 2 mm / m; tshuaj xyuas qhov tawg / kev daws teeb meem ua ntej tso.
  • Roj filling:Kuaj roj zoo ua ntej; kho cov roj theem ib puag ncig qhov kub thiab txias (tso qhov chaw nthuav dav); sawv siab dua lossis sib npaug li 24 teev rau degassing ua ntej energising.
  • Qhov cua:Sab nraum zoov - khaws 1.5 m tshem tawm, tsis txhob muaj qhov thaiv, muab qhov ntxoov ntxoo yog tias xav tau. Sab Hauv Tsev - xyuas kom muaj cua ntws los txwv qhov kub ntawm chav tsev tsawg dua lossis sib npaug li 10 K; ntxiv cov cua tshuab cua yog tias ntuj tsis txaus.

 

Kev tu

  • Txhua lub lis piam:Tshawb xyuas welds, flanges, li qub rau cov roj stains; txheeb xyuas qhov ntsuas roj; sab saum toj roj kub Tsawg dua los yog sib npaug rau 85℃(ntawm 20℃ambient); mloog cov suab txawv txawv.
  • Ua ntej-lub caij ntuj sov:Ntxuav radiator fins; xeem kiv cua ua kom logic; rov kho flange bolts.
  • Kev kuaj roj:Txhua xyoo kuaj kev tawg voltage, noo noo, acid nqi, dielectric poob; luv mus rau 6 lub hlis hauv cov xwm txheej hnyav. Rwb thaiv tsev tsis kam kuaj txhua 2 xyoos.

 

Cov Lus Qhia Txog Kev Kho Mob:Tsis txhob tos kom pom cov teeb meem transformer ua ntej kuaj cov roj. Feem ntau, kev sib kis ntawm cov dej noo thiab rwb thaiv tsev tsis zoo tuaj yeem tshawb pom los ntawm cov roj tshuaj ntsuam xyuas lub hlis ua ntej qhov kub thiab txias los yog rwb thaiv tsev tsis ua haujlwm tau pom.

 

Kev Tiv Thaiv Thaum Muaj Xwm Ceev rau Roj Leakage & Overheating

 

Roj to:Nrhiav qhov xau. Rau kev foob seepage, tusyees retighten flange bolts (tsis txhob overtighten). Rau me me weld to, thov polymer sealant online yam tsis muaj kev kaw. Yog tias muaj roj ntau heev los yog ceev ceev, txiav fais fab tam sim ntawd thiab npaj kev saib xyuas.

 

Overheating: When oil temperature exceeds normal by >10℃los yog nce ntxiv, xyuas cov khoom thauj tam sim no thiab peb-theem tshuav nyiaj li cas; txheeb xyuas qhov ua haujlwm txias (rau ONAF, manually pib kiv cua). Yog tias qhov kub thiab txias tshwm sim tom qab lwm yam raug txiav tawm, xav tias muaj kev ua txhaum sab hauv - txo qis lossis kaw, thiab ua cov tshuaj yaj yeeb yaj kiab (DGA) rau kev kuaj mob.

 

Specifications rau 1500kVA Transformers

Rated zog 1500 kVA ua
Rating Thawj Voltage 2.4 - 34.5 kV
Secondary Voltage 480/277V
400/230V
380/220V
Customized
Ntau zaus 50/60Hz
Vector Group Dyn11, Yyn0, Dyn5
Cov khoom siv winding Aluminium / tooj liab
Kev ua tau zoo Raws li IEEE, Doe 2016, CAS Std lossis Customized
Qhov voltage impedance Nominal 2% lossis Customized 1.1 - 5.75%
Qhov siab Tsawg dua lossis sib npaug li 1,000m lossis Customized
Xim ANSI 70 Lub teeb grey / Munsell 7GY3.29 / 1.5 lossis customized, thiab lwm yam
Cov khoom siv tank Mild Steel, 304 Stainless Hlau
Insulating Roj Qhov hnyav 7 80kg
Qhov hnyav tag nrho 4 300kg
Daim Ntawv Qhia Dimensions (L × W × H) hauv. 2550 × 1600 × 2400 (mm)

 

Npaj los qhia txog 1500kVA transformer uas nyob ruaj khov rau 20+ xyoo?

Tsis txhob tso koj lub zog tseem ceeb hauv kev tsim kom muaj caij nyoog. GNEE Electric muab cov kev hloov pauv tau zoo, IEC-certified 1500kVA transformers engineered rau koj qhov chaw raws li qhov chaw - nrog 100% tooj liab windings, leak-proof tsim, thiab yeem yuam kom txias rau qhov xav tau ib puag ncig.

Download Technical Datasheet

 

Tau txais koj qhov Kev Cai Quote- Qhia koj cov ntaub ntawv thauj khoom thiab cov xwm txheej ib puag ncig, thiab tau txais cov lus pom zoo tsis pub dhau 48 teev.

 

1500kVA Oil-Immersed Distribution Transformer

1500kVA Transformers

1500kVA Oil-Immersed Distribution Transformer

 

FAQ

Cov roj me me ntawm 1500kVA transformer puas tuaj yeem ua haujlwm ntxiv?

Kev pom me ntsis yam tsis muaj roj txuas ntxiv tuaj yeem ua haujlwm ib ntus, tab sis cov roj theem thiab kev txhim kho to yuav tsum tau saib xyuas zoo. Nws raug nquahu kom npaj kev saib xyuas sai li sai tau. Yog tias cov roj qib qis qis qis qis qis tshaj qhov ceeb toom kab, lub tshuab yuav tsum raug kaw tam sim ntawd, vim tias cov cua nkag yuav raug cuam tshuam los ntawm kev puas tsuaj ntawm rwb thaiv tsev.

 

 

Dab tsi kub tus nqi txhais tau tias txaus ntshai overheating rau 1500kVA roj immersed transformer?

Raws li IEC 60076-2, nyob rau hauv 40℃siab tshaj ambient kub, sab saum toj roj kub ntawm 100℃thiab winding nruab nrab kub ntawm 105℃yog cov rated txwv qhov tseem ceeb. Thaum cov roj saum toj kawg nkaus kub siab tshaj 95℃los yog txuas ntxiv nce mus rau qhov txawv txav, nws suav tias yog qhov txaus ntshai overheating xeev, thiab cov load yuav tsum raug txo los yog lub tshuab yuav tsum raug kaw tam sim ntawd.

 

 

Puas yog ONAF yuam cua txias tsim nyog rau lub caij ntuj sov siab - siv kub?

Rau cov cheeb tsam uas lub caij ntuj sov siab tshaj ambient kub tshaj 38 degree, los yog transformers khiav ntawm 90% + load rau lub sij hawm ntev, ONAF txias yog xav pom zoo. Cov kiv cua yuam tuaj yeem txo cov roj saum toj kawg nkaus los ntawm 10-15 degree, uas tuaj yeem ua kom tsis txhob dhau - qhov kub thiab txias thiab ua kom lub neej ntev ntawm rwb thaiv tsev.

 

 

Yuav ua li cas txheeb xyuas tooj liab winding thiab aluminium winding transformer sai sai ntawm qhov chaw?

Txoj kev raug tshaj plaws yog ntsuas qhov DC tsis kam ntawm winding thiab sib piv nrog tus qauv tsis kam ntawm tooj liab winding. Tsis tas li ntawd, aluminium winding transformers feem ntau yog 20% ​​-30% sib zog dua li cov khoom siv tooj liab tag nrho ntawm tib lub peev xwm, thiab cov nqi poob ntawm lub npe feem ntau yog siab dua. Nws tseem tuaj yeem raug txheeb xyuas los ntawm kev txheeb xyuas cov ntaub ntawv pov thawj raw khoom ntawm cov chaw tsim khoom.

 

Dab tsi yog qhov tam sim no ntawm 1500kVA transformer?

Ntawm 480V, 1500 kVA peb -theem transformer muaj tag nrho cov khoom tam sim no ntawm1804.3 ib.

 

Dab tsi yog qhov ua tau zoo ntawm 1500kVA Peb Theem Roj Immersed Transformer?

A 1500kVA Peb Theem Roj Immersed Transformer feem ntau ua tiav qhov ua tau zoo ntawm 98% mus rau 99%, nyob ntawm qhov chaw thauj khoom thiab tsim qauv zoo.

 

Lub neej kev pab cuam ntawm 1500kVA roj immersed transformer yog dab tsi?

Lub qhov dej- khaws cia 1500kVA roj immersed transformer tuaj yeem ua haujlwm tau zoo rau 20 txog 30 xyoo lossis ntev dua.

 

Xa kev nug