50kva / 10kv laminated tub ntxhais faib khoom thauj

50kva / 10kv laminated tub ntxhais faib khoom thauj

Khoom npe: 50 KVA / 10 KV laminated tub ntxhais faib khoom
Peev Xwm: 50 KVA
Lub Xyoo Nyiaj: 2024
Lub teb chaws: Mexico
Daim Ntawv Thov Qho: Kev Siv Hluav Taws Xob rau cov kab ntau lawm.
Cov lus piav qhia tau zoo dua: Ntau qhov kub thiab txias ntau ntxiv ({}}}}} degree) ua kom muaj kev tswj hwm txhim khu kev qha nyob rau hauv huab cua huab cua.
Xa kev nug
Tsham tam sim no

Muaj lus nug? GNEE cov neeg muag khoom muaj nyob rau hauv kev sib tham tam sim no

Xa E-mail:sales@gneeelectric.com

Tel:+8615824687445

 

 

Cov Khoom Muag Khoom

‌

50KVA/10KV Laminated Core Distribution Transformer

No Laminated Core faib Transformer Adopts Laminated Corechnology Technology, muab cov cench core core)

‌Tsawg-unc tsim: Optimized Interlayer rwb thaiv tsev thiab sib nqus Circuit Court qauv txo eddy dhau 30%, outperforming cov khoom hloov pauv-tub ntxhais hloov pauv.

‌Muaj kev yoog tau: Withstands ± 10% voltage fluctive nyob rau hauv 10 kv rated voltage, kom muaj kev ruaj khov nyob rau hauv cov xwm txheej tsis ruaj khov.

‌Compact qauv: Ua kom muaj kev kub ntxhov ntawm lamination txo cov khoom siv roj silicon li 20% piv rau cov peev txheej-cov qauv ntawm cov peev txheej, simpecting kev thauj mus los thiab kev teeb tsa sim.

‌Kev Ua Raws Ib puag ncig: Ua tau raws li IEC 60076 tus qauv; Roj-dawb kev pheej hmoo ib puag ncig kev pheej hmoo.

‌Modular Taus: Kev txhawb nqa kev ua haujlwm sib txuas rau kev yoog raws kev yoog raws li lub zog xav tau txij li 50 kva rau 500 kva.

 

 

 

Cov khoom lag luam parameter

 

Kev Muaj Peev Xwm (KVA) H.V. (KV) Tapping ntau L.V. (KV) Vector Group Poob (kw) Tsis muaj-thauj khoom tam sim no (%) Impedance voltage (%) Weight (kg)
Thauj khoom poob Tsis muaj-thau khoom poob roj Tag nrho
30 6
6.3
10
10.5
11
±5%
±2×2.5%
0.4 Yyn 0
Dyn11
0.6 0.10 0.80 4 75 295
50 0.87 0.13 0.75 90 390
63 1.04 0.15 0.70 100 450
80 1.25 0.18 0.70 105 485
100 1.50 0.20 0.65 115 555
125 1.80 0.24 0.65 135 660
160 2.20 0.27 0.60 150 790
200 2.60 0.33 0.60 190 940
250 3.05 0.40 0.50 205 1095
315 3.65 0.48 0.45 250 1255
400 4.30 0.57 0.40 265 1375
500 5.10 0.68 0.40 300 1680
630 6.20 0.81 0.40 410 1850
800 7.50 0.98 0.40 500 2260
1000 10.30 1.15 0.30 4.5 510 2390
1250 12.00 1.36 0.30 570 3370
1600 14.50 1.64 0.30 635 3950
2000 17.50 2.05 0.50 750 4715
2500 21.20 2.50 0.40 800 5005

 

 

Hu rau tam sim no

 

 

 

Cov duab kom ntxaws

 

50KVA/10KV Laminated Core Distribution Transformer

 

 

Siv tau teb

 

Cov lus dag ntxias tus tub ntxhais ntawm Lamined Transformer yog siv dav hauv:

‌MUAJ MUAJ TSEV HAB: Lub chaw faib hluav taws xob tiv thaiv hluav taws xob rau cov ntsiab lus, thiab chaw nres nkoj, hais txog kev txuag hluav taws xob thiab ruaj khov nyob rau hauv high-load scararios.

‌Txuas Ntxiv Hluav Taws Xob: Daim phiaj-khi cov khoom siv rau hnub ci thiab cua ua liaj ua teb; Nws cov kev tsim qis-ploj maximizes txuas ntxiv hluav taws xob siv.

‌Chaw Taws Teeb Thaj Chaw Hluav Taws Xob: Lub teeb yuag silicon hlau laminated roj hmab-immersed transformer suformous toj roob hauv pes, thaum nws tus tub rog muaj kev ntseeg siab ntseeg tau.

‌Ntse daim phiaj hloov kho: Tau tshaj nrog Smart Meters thiab Automated Tswj SystemS, rooj sib tham IOT-DRIVIT GRID MIDY xav tau.

 

50KVA/10KV Laminated Core Distribution Transformer

 

 

 

Daim Qhia Qhia Txog

 

 

Ua raws li cov theem no los nruab qhovLaminated tub ntxhais faib khoom hloov pauv‌:
50KVA/10KV Laminated Core Distribution Transformer
01.

Tsis yog kev sib cuag tshuab hluav taws xob

Lub Foundation Npaj‌:

Ua kom muaj lub tiaj tus cev teeb tsa nrog cov chaw muaj hluav taws kub tshwj tseg (tsawg kawg 1 meter los ntawm phab ntsa).

Nteg ib lub hauv paus insulated nrog grounding tsis kam dua lossis sib npaug rau 4ω.

‌Cov Khoom Siv Zov‌:

Siv forklifts lossis cranes rau txoj hauj lwm cov khoom siv silicon laminated roj-immersed transformer maj mam muab, zam kev deformation.

Soj ntsuam cov ntsaws ruaj ruaj kom tiv thaiv kev ya raws lossis hmoov av ingress thaum lub caij pib.

02.

Kev Sib Txuas Hluav Taws Xob‌:

Txuas cov hluav taws xob siab (10 kV) thiab qis-voltage (400 v) terminals toj ib kab kos duab, ua kom nruj.

Nruab cov teeb meem kev ntes thiab kev tiv thaiv ntau dhau, ua raws li cov lej hluav taws xob hauv nroog.

‌Commissioning & kuaj‌:

Ntsuas cov rwb thaiv tsev tsis kam (ntau dua lossis sib npaug rau 200 mω) nrog manohmermeter ua ntej ua kom muaj zog.

Ua ib qho {1- teev tsis muaj-thauj khoom, saib xyuas qhov kub thiab kub tshaj lossis sib npaug ntawm 55 dB); xyuas kom tsis muaj kev txawv txav lossis tsw ntxhiab.

‌Kev Nyab Xeeb Kev Nyab Xeeb: Yuav tsum hnav cov tshuaj insulated insulated thaum lub sijhawm teeb tsa thiab tsis txhob sib cuag nrog High-voltage tearinals.

50KVA/10KV Laminated Core Distribution Transformer

 

Hu rau tam sim no

 

 

 

Vim li cas thiaj xaiv peb?

 

Gnee pawg:

Ntiaj Teb Transformer mov txuas nrog cov kws muaj txuj ci ({0}} tam sim no

Pom nyob rau hauv 2 {0 08, GNEE pab pawg tau dhau los ntawm ib tus tub luam hauv ntiaj teb no rau lub ntiaj teb cov khoom siv tswj cov kws tshaj lij. Raws li cov tho kev hauv kev sib koom ua ke ntawm cov qauv hlau, cov pab pawg tau tsim kho kom zoo, thiab kev ua kom haum rau cov khoom lag luam tshiab hauv ntiaj teb hloov hluav taws xob. Nyob rau hauv lub caij nyoog ntawm kev lag luam 4.0, Gnee pawg tau nrawm rau nws lub hom phiaj ntawm kev ua lub ntiaj teb kev lag luam muaj txiaj ntsig thiab kev hloov kho cov khoom ntsuab.

 

SGS Daim Ntawv Pov Thawj Ntawv Pov Thawj

 

50KVA/10KV Laminated Core Distribution Transformer
Ib Cheeb Tsam Ntau Lawm

 

50KVA/10KV Laminated Core Distribution Transformer

 

Peb Lub Hoobkas

 

50KVA/10KV Laminated Core Distribution Transformer

​

Ntim thiab Xa Tawm

 

50KVA/10KV Laminated Core Distribution Transformer

‌‌

 

Cov FAQ
 

Q1: Yuav ua li cas xaiv ntawm cov roj-immersed, qhuav-hom, lossis amorphous alloy transformers raws li kev xav tau?

A: Roj-raus hloov pauv (piv txwv li, 30-2500 kva / 10 kV roj-raus peb-theem dual-winding):
Muaj feem xyuam nrog cov xwm txheej: Cov chaw tsim khoom loj, cov chaw hloov, sab nraum zoov high-voltage fais fab faib.
Cov txiaj ntsig zoo: Cov tshav kub zoo heev tsis haum rau cov thauj khoom siab thiab cov chaw kub kub, tab sis xav tau kev tiv thaiv hluav taws thiab roj tsis ceev faj.
Qhuav-hom hloov pauv (piv txwv li, epoxy cob-cam khwb cia hom, qhuav hom dual-winding):
Muaj feem xyuam nrog cov xwm txheej: Hauv sab hauv tsev (piv txwv li, cov chaw zov me nyuam, cov tsev lag luam lag luam), ib puag ncig uas muaj kev nyab xeeb cov hluav taws kom nruj.
Cov txiaj ntsig: Tsis muaj rwb thaiv tsev roj, ua qias tuaj-dawb, tsis muaj suab paj nruag, tab sis yuav tsum muaj kev tso pa tawm rau tshav kub dissipation.
Amorphous Alloy Transformers (piv txwv li, Amorphous Alloy Qhuav-Hom):
Muaj feem xyuam nrog cov xwm txheej: Daim phiaj kawg daim ntawv thov, Khoom siv hluav taws xob nyob deb nroog, hluav taws xob muaj zog.
Qhov Zoo: Txo tsis muaj lub nra tsis dhau 70%, siab dua li cov kev hloov pauv ib txwm muaj, zoo rau kev ua haujlwm ntev tsawg.

Q2: Cov khoom siv twg haum rau Rectifier hloov pauv ({}} kva rectifier hom)?

A: Tsim qauv tshwj xeeb rau cov khoom siv rectifier, xws li:
Electrolating kab, elecolytic cells.
Aluminium / Mawb Ectrolysis Los Ntau Lawm.
DC lub cev muaj zog tsav tshuab.
Nta: Peb-theem tswv yim, kho tau DC voltage tso zis. Nco tseg: Harmonic loads yuav cuam tshuam kev ua haujlwm.

Q3: Dab tsi yog qhov sib txawv ntawm cov khoom ua ntej prefabricate (European style) thiab ua ke hloov (sib xyaw hom)?

A: Prefabricatedace:
Kev sib xyaw ua ke: suav nrog hloov pauv, cov khoom siv tsawg, thiab cov kev tiv thaiv kev tiv thaiv Pre-teeb tsa hauv huab cua huab cua / hluav taws-resistant freatures.
Muaj feem xyuam nrog cov xwm txheej: Siv sijhawm sai sai sai (piv txwv li cov chaw tsim kho kev tsim kho, chaw taws teeb chaw deb).
Ua ke hloov pauv:
Kev sib xyaw ua ke: Feem ntau sib xyaw ua ke hloov pauv, ntsuas ntsuas cov khoom siv, thiab cov cuab yeej tiv thaiv kom yooj yim yooj yim yooj yim muab cov khoom xa tawm.
Muaj feem xyuam nrog cov xwm txheej: Lub zog faib cov chaw zov me me rau cov chaw tsim khoom me me / nruab nrab lossis ua lag luam.

Q4: Dab tsi yog Voltage hloov kho txoj kev rau 30-2500 kva dual-winding tsis yog hloov hluav taws xob hloov?

A: Tsis hloov hom: Tsau tawm cov zis volfage teeb ntawm lub Hoobkas (piv txwv li 10 kV tswv yim → 400 V tawm); tsis muaj kev hloov kho ntawm kev hloov kho.
Muaj feem xyuam nrog cov xwm txheej: ruaj khov voltage ib puag ncig muaj tsawg heev thauj khoom hloov pauv (piv txwv li cov kab ntau lawm).
Rau cov hluav taws xob kev kho kom haum, xaiv on-load kais-hloov pauv hloov pauv (kho tau).

Q5: Dab tsi yog qhov kub tsis kam thiab lub neej ntawm epoxy resin-cam khwb cia qhuav hloov khoom?

A: Kub Kuj: Chav Kawm F (155 degree) lossis chav kawm h (180 degree), nrog dhau lub peev xwm txog li 1.5 × rated zog.
LIFPANGAN: Tshaj 20 xyoo nyob rau hauv kev ua haujlwm ib txwm, tab sis yuav tsum tau tshuaj xyuas ib txwm muaj cua tshuab cua txias.

 

Hu rau tam sim no

 

 

Cim npe nrov: 50KVA / 10KV Laminated Coreper Transformation, Tuam Tshoj 50Kva / 10KV Laminated Coreper Cov Chaw Tsim Tshuaj, Chaw muag khoom, Hoobkas

Xa kev nug