JP Sab nraum zoov faib lub thawv sib koom ua ke metering, cov khoom xa tawm, thiab cov nyiaj them rov qab hluav taws xob nrog luv luv -circuit, overload, overvoltage, thiab tiv thaiv to. Rated rau 30-400 kVA transformers, AC 400V, IP54 enclosure. Txoj kev daws teeb meem zoo tshaj plaws rau kev hloov hluav taws xob hauv nroog thiab nyob deb nroog.
Xa kev nug
Tsham tam sim no

Muaj lus nug? GNEE cov neeg muag khoom muaj nyob rau hauv kev sib tham tam sim no

Xa E-mail:sales@gneeelectric.com

Tel:+8615824687445

Henan GNEE Electric Co., Ltd. yog ib qho ntawm feem txhim khu kev qha manufacturers thiab lwm tus neeg ntawm jp sab nraum zoov integrated faib lub thawv nyob rau hauv Suav teb. Yog hais tias koj yuav mus yuav customized jp sab nraum zoov integrated faib lub thawv ua nyob rau hauv Suav teb, txais tos kom tau txais cov lus hais los ntawm peb lub hoobkas. Cov khoom zoo thiab tus nqi tsim nyog muaj.

 

Dab tsi yogJP sab nraum zoov integrated faib lub thawv?

CovJP sab nraum zoov integrated faib lub thawvyog ib qho khoom siv hluav taws xob sab nraum zoov uas sib xyaw ua ke metering, outgo feeders, thiab reactive zog them rau hauv ib chav tsev. Nws muab kev tiv thaiv tag nrho suav nrog luv luv - tiv thaiv Circuit Court, tiv thaiv overload, tiv thaiv overvoltage, thiab qhov seem tam sim no (tshwj xeeb) tiv thaiv.

 

Nrog nws qhov loj me, zoo nkauj zoo nkauj, thiab kev tsim qauv tsim, JP faib lub thawv tau teeb tsa rau ntawm tus ncej ntawm sab nraum zoov ncej-mounted transformers, ua rau nws yog qhov zoo tshaj plaws tshiab - tiam khoom faib rau hauv nroog thiab nyob deb nroog cov phiaj xwm kev hloov hluav taws xob.

 JP Distribution Box

Xav tau lub thawv ntim khoom JP customized rau koj qhov phiaj xwm phiaj xwm?

Tau txais lub Hoobkas- tus nqi ncaj qha nrog kev xa khoom thoob ntiaj teb thiab cov ntaub ntawv xa tawm tag nrho.

 Tau txais Quote tam sim no

Cov yam ntxwv tseem ceeb ntawm ib saib

Tag nrho -hauv-Ib Kev Sib Koom

Metering, feeders, thiab reactive zog them nyiaj nyob rau hauv ib tug enclosure

Full Protection Suite

Luv -circuit, overload, overvoltage, thiab tiv thaiv to

IP54 Sab nraum zoov Rated

Waterproof, plua plav- pov thawj, tiv thaiv- xeb stainless hlau enclosure

30-400 kVA Ntau

Txhawb ntau yam ntawm kev faib khoom transformer muaj peev xwm

Thaum tshav kub kub & Condensation pov thawj

Honeycomb qauv ob - txheej phaj rau thermal rwb thaiv tsev

20-Xyoo Anti-Corrosion

Kub-dip galvanized sab hauv cov khoom, tshwj xeeb vuam tshuab

Qauv thiab txhais

Model And Definitions

Cov Qauv & Ua raws li JP Distribution Box

JP sab nraum zoov integrated faib lub thawv yog tsim nyob rau hauv nruj raws li nram no lub teb chaws thiab thoob ntiaj teb cov qauv, ua kom ntseeg tau kev ua tau zoo thiab kev cai raws li txoj cai rau daim phiaj tej yaam num:

 

  • GB/T 7251.2-2023- Tsawg-voltage switchgear thiab controlgear assemblies, Part 2: Fais fab switchgear thiab controlgear assemblies for distribution
  • GB/T 15576-2020- Tsawg-voltage reactive fais fab kev them nqi sib dhos
  • IEC 61439-1: Cov- Tsawg-voltage switchgear thiab controlgear assemblies, General rules (International standard)

 

Cov yam ntxwv ntawm JP Outdoor Distribution Box

JP sab nraum zoov integrated faib lub thawv yog engineered rau durability, kev nyab xeeb, thiab yooj yim ntawm txij nkawm. Nws txoj kev tsim kho ruaj khov ua kom ntev - lub sijhawm ua haujlwm txhim khu kev qha hauv qhov chaw sab nraum zoov hnyav:

Box structure diagram

1. Kev tsim kho vaj tse

Lub thawv qauv muaj nyob rau hauv ob qho tib sintsug thiab kab rov tavkev teeb tsa. Lub plhaub yog fabricated los ntawm2 hli siab - zoo stainless hlau phajsiv ntau -fold flanging txheej txheem. Ib qho kev xaiv stainless hlau ob npaug - txheej txheej phaj nrog honeycomb qauv muab cov nplaim hluav taws kub hnyiab, ib puag ncig kev nyab xeeb, rwb thaiv tsev kub, thiab tiv thaiv -kev ua tau zoo.

2. Welding & Surface Treatment

Tshwj xeeb stainless hlau vuam tshuab ua kom muaj zog tag nrho cov qauv. Qhov saum npoo yog du thiab huv si zoo li daim iav, tsis muaj qhov pom kev vuam. Internal mounting beams thiab daim hlau siv akub-dip galvanized txheej txheem, lav20 xyoo ntawm corrosion- ua haujlwm dawb.

3. Qhov Rooj Tsim & Kev Ruaj Ntseg

Pem hauv ntej thiab nraub qaum qhov rooj muab kev nkag tau yooj yim rau kev ua haujlwm, tshuaj xyuas, thiab tu. Txhua lub qhov rooj yog nyob ib puag ncig los ntawm lub siab - elasticity, laus- tiv taus sealing sawb thiab nruab nrogob lub qhov rooj xauv(pom thiab zais / tiv thaiv- tub sab). Lub xauv pom muaj xws li tiv thaiv- thaiv, xeb- pov thawj los nag. Lub metering chamber yog tag nrho nrog atxhuas sealing ntaus ntawvlos tiv thaiv tampering.

 

4. Kev tswj qhov cua & Cable

Hauv qab ntawm lub thawv yog xuas nrig nrog lub qhov cua thiab lub qhov hluav taws xob cable. Sab saum toj nta qhov cua raws thiab xaim mesh. Cable nkag lub tes tsho nyob rau sab ntawm lub thawv tiv thaiv los nag ingress thiab txawv teb chaws teeb meem. Qhov kev tsim no ua tiav tiavwaterproof, plua plav- pov thawj, tiv thaiv- xeb, thiab tiv thaiv- txawv teb chaws - teeb meemtiv thaiv, nyob ntawmIP54.

Vertical box dimensions
Installation Diagram

5. Cov khoom siv sab hauv

Lub txee muaj ib qho qhib- hom riam hloov (kab cais), moulded- rooj plaub Circuit Court breakers, fuses, residual tam sim no tiv thaiv Circuit Court breakers, composite keyboards, ib tug ntse reactive hwj chim them nyiaj xws li, thiab lub hwj chim capacitors. Lub busbar tseem ceeb yog nyob rau saum lub txee. Tooj liab busbars, N busbars, thiab PE busbars yog ua los ntawm liab qab tooj liab nrog tshav kub-shrink tubing ntawm cov seem tseem ceeb. Lub hwj chim capacitor bank yog configurable nyob rau hauv ob qho tib si Δ (delta) los yog Y (hnub qub) kev npaj.

Kev cai configurations muaj rau ntsug lossis kab rov tav installation

Qhia rau peb koj lub peev xwm transformer thiab tus lej xov tooj - peb yuav tsim rau spec.

Thov Configuration

 

Technical Parameters ntawm JP Outdoor Integrated Distribution Box

Cov lus hauv qab no nthuav qhia qhov ua tiav kev qhia tshwj xeeb rau JP series sab nraum zoov kev sib koom ua ke lub thawv. Cov kev tsis sib xws yuav txawv raws li qhov project configurations thiab scheme tooj.

Parameter Chav tsev Tus nqi
Transformer muaj peev xwm kVA ua 30 – 400
Rated Ua Haujlwm Voltage (Ue) V AC 400
Rated rwb thaiv tsev Voltage (Ui) V 690
Txhawb Circuit Court voltage V AC 220 / AC 380
Rated Zaus Hz 50
Rated Tam sim no A Tsawg dua lossis sib npaug li 630
Rated Short-Lub Sijhawm Nrog Tam Sim No (Icw) kA 15
Rated Leakage Kev Ua Haujlwm Tam Sim No mA 30-300 (kho tau)
Capacitor Rated Peev Xwm (Qc) kvar 20 – 180
Txoj kev them nyiaj - Peb-theem & ib zaug-theem ua ke
Capacitor Switching Element - Composite hloov
Qib tiv thaiv - IP54
Sab hauv / Sab Nraud Hom - Sab nraum zoov
Capacitor Configuration - Δ (delta) lossis Y (lub hnub qub)

 

Kev khiav hauj lwm ib puag ncig rau JP Distribution Box

JP sab nraum zoov kev sib koom ua ke lub thawv yog tsim los ua haujlwm kom ntseeg tau raws li cov xwm txheej hauv qab no. Rau kev teeb tsa tshaj li qhov tsis sib xws, cov kev cai daws teeb meem muaj nyob rau ntawm kev sab laj.

Environmental condition Specification
Ambient Kub -25℃rau +40 degree
Cua txheeb ze humidity (qhov nruab nrab txhua hnub) Tsawg dua los yog sib npaug li 90%
Cua txheeb ze humidity (ib hlis nruab nrab) Tsawg dua los yog sib npaug li 90%
Qhov siab Tsawg dua los yog sib npaug li 2000 m (kev cai xaiv txog li 3000 m)
Kev vibration & cuam tshuam Muab tso rau hauv qhov chaw tsis muaj kev vibration hnyav thiab cuam tshuam
Corrosive Gas Dawb los ntawm corrosive gases thiab pom muaj kab mob

Nco tseg: Yog tias cov xwm txheej saum toj no dhau lawm, kev cai teeb tsa muaj. Thov sab laj nrog peb pab neeg engineering rau cov kev pabcuam tshwj xeeb.

 

Daim ntawv thov ntawm JP Sab Nraud Integrated Distribution Box

JP sab nraum zoov kev sib koom ua ke lub thawv yog ntau yam kev tswj hwm lub thawv tsim nyog rau ntau yam kev faib hluav taws xob, ntsuas, kev tiv thaiv, thiab kev siv hluav taws xob rov ua haujlwm. Nws cov thawj daim ntawv thov thaj chaw muaj xws li:

  • Urban power grid transformation
  • Rural grid upgrading tej yaam num
  • Substations thiab faib nodes
  • Factories thiab chaw tsim khoom
  • Industrial thiab mining enterprises
  • Loj -teev fais fab nroj tsuag
  • Petroleum thiab chemical chaw
  • Major steel mills
  • High-Rise building power centers
  • Reactive zog them nyiaj systems
  • Kev faib hluav taws xob hauv zej zog
  • Kev lag luam tsev metering

JP faib lub thawv tshwj xeeb yog tsim rauncej-mounted transformer installationsqhov chaw muaj kev txwv thiab ntau- kev sib koom ua ke muab qhov txiaj ntsig zoo tshaj plaws. Nws ua haujlwm raws li qhov tseem ceeb ntawm kev sib txuas ntawm cov khoom siv hluav taws xob thiab qhov kawg - cov neeg siv khoom thauj, muab kev ntsuas ntsuas, kev tiv thaiv, thiab kev txhim kho lub zog zoo hauv ib pob, compact, weatherproof.

 

Yuav Thov Li Cas JP Sab Nraud Integrated Distribution Box

Txhawm rau kom ntseeg tau tias peb xa lub thawv xa khoom JP uas haum raws li koj qhov kev xav tau, thov muab cov ntaub ntawv hauv qab no thaum xa koj cov lus nug:

  1. Khoom qauv- JP series npe thiab transformer muaj peev xwm
  2. Hom qauv- Vertical lossis kab rov tav configuration
  3. Main Circuit scheme naj npawb- Xaiv los ntawm cov phiaj xwm 01–10 raws li kev muaj peev xwm thiab kev xav tau
  4. Khoom specifications- Cov qauv thiab cov kev tsis sib xws ntawm cov khoom tseem ceeb (breakers, capacitors, thiab lwm yam)
  5. Ntau- Tus naj npawb ntawm cov units yuav tsum tau
  6. Cov cai tshwj xeeb- Txhua yam kev cai tshwj xeeb, qhov siab lossis qhov kub thiab txias, lossis cov yam ntxwv ntxiv

 

Peb pab neeg ua haujlwm engineering yuav tshuaj xyuas koj cov kev xav tau thiab muab cov lus qhia ntxaws hauv 24 teev, suav nrog kev kos duab kos duab thiab sijhawm xa khoom.

 

JP Outdoor Integrated Distribution Box

JP Outdoor Integrated Distribution Box

Tau txais koj lub JP Sab Nraud Kev Sib Txuas Sib Txuas Sib Tham Sib Tham Hnub no

Factory- cov khoom xa ncaj qha nrog kev xa khoom thoob ntiaj teb, cov ntaub ntawv xa tawm tag nrho, thiab 12- lub hlis lav. Qhia rau peb koj lub peev xwm transformer thiab teeb tsa - tau txais cov lus hais meej hauv 24 teev.

Xa lus nug tam sim no

FAQ

Dab tsi yog qib kev tiv thaiv ntawm JP sab nraum zoov kev sib koom ua ke lub thawv?

JP sab nraum zoov sib xyaw ua ke lub thawv muaj kev tiv thaiv qib IP54, muab cov dej tsis zoo, plua plav- pov thawj, tiv thaiv- xeb, thiab tiv thaiv- txawv teb chaws- tiv thaiv teeb meem. Lub kaw lus yog ua los ntawm 2 hli siab - zoo stainless hlau phaj nrog ntau - txheej txheem flanging los yog stainless hlau ob chav sandwich phaj nrog honeycomb qauv rau nplaim taws retardancy, tshav kub rwb thaiv tsev, thiab anti- condensation kev ua tau zoo. Cov khoom siv sab hauv siv kub -dip galvanized kev kho mob rau 20 xyoo corrosion kuj.

 

Dab tsi transformer muaj peev xwm ntau npaum li cas JP faib lub thawv txhawb nqa?

JP sab nraum zoov integrated faib lub thawv txhawb transformer muaj peev xwm ntawm 30 mus rau 400 kVA. Nws muaj nyob rau hauv ob qho tib si kab rov tav thiab ntsug configurations nrog ntau lub tswv yim tus lej (01-10) kom haum raws li qhov sib txawv muaj peev xwm thiab cov kev xav tau ntawm kev teeb tsa. Rau qhov muaj peev xwm sab nraud qhov no, cov kev cai daws teeb meem muaj nyob rau ntawm kev sab laj nrog peb pab neeg ua haujlwm engineering.

 

Dab tsi yog qhov txawv ntawm kab rov tav thiab ntsug JP faib lub thawv?

Kab rov tav JP faib lub thawv yog dav dua thiab luv dua, feem ntau yog siv thaum tus ncej qhov chaw tso cai rau qhov dav dav mounting hneev taw. Kev teeb tsa ntsug yog siab dua thiab nqaim, zoo tagnrho rau kev teeb tsa nrog qhov chaw kab rov tav. Ob hom muaj kev ua haujlwm zoo ib yam thiab qib kev tiv thaiv. Qhov kev xaiv nyob ntawm qhov ntev ntawm tus ncej, lub peev xwm transformer, thiab qhov chaw nyob. Kab rov tav qhov ntev ntawm 800 × 450 × 700 mm txog 1100 × 600 × 800 mm; ntsug qhov ntev li ntawm 600 × 450 × 1000 mm txog 800 × 600 × 1100 mm.

 

Cim npe nrov: jp sab nraum zoov integrated tis lub thawv, Tuam Tshoj jp sab nraum zoov integrated faib lub thawv manufacturers, lwm tus neeg, Hoobkas