Prefabricated Substation Rau Zog Cia Systems
Muaj lus nug? GNEE cov neeg muag khoom muaj nyob rau hauv kev sib tham tam sim no
Xa E-mail:sales@gneeelectric.com
Tel:+8615824687445
Henan GNEE Electric Co., Ltd. yog ib qho ntawm feem txhim khu kev qha manufacturers thiab lwm tus neeg ntawm prefabricated substation rau lub zog cia tshuab nyob rau hauv Suav teb. Yog tias koj yuav mus yuav customized prefabricated substation rau lub zog cia tshuab ua nyob rau hauv Suav teb, txais tos kom tau txais cov lus hais los ntawm peb lub hoobkas. Cov khoom zoo thiab tus nqi tsim nyog muaj.
Dab tsi yog Prefabricated Substation rau Lub Zog Cia?
Aprefabricated substation rau lub zog ciayog ib qho kev sib koom ua ke, thauj khoom hluav taws xob hauv lub tshuab hluav taws xob, MV switchgear, LV switchgear, kev tiv thaiv thiab cov cuab yeej pabcuam tau ua tiav, xaim thiab lub Hoobkas- kuaj ua ntej xa khoom. Piv nrog rau cov pa pej xeem- tsim cov chaw nres tsheb, lub ESS substation tuaj txog ntawm qhov chaw nrog Lub Hoobkas Txais Kev Xeem (FAT) ua tiav; qhov chaw ua haujlwm tsuas yog siv rau kev npaj lub hauv paus, hoisting, cable termination thiab kawg daim phiaj commissioning.

Cov qauv tsim muaj xws li cov qauv ntim ntim khoom, European-style compact box- hom qauv thiab skid- mounted units, tso cai hloov tau yooj yim rau kev sib txawv ntawm qhov chaw layouts thiab thauj txwv. Txawm hais tias siv rau kev siv hluav taws xob- nplai BESS cov nroj tsuag lossis kev lag luam thiab kev lag luam (C&I) ESS daim ntawv thov, chav tsev yog tsim los rau ntsaws- thiab- ua si kab sib txuas nrog yam tsawg kawg nkaus ntawm - chaw ua haujlwm.
Cov Cheebtsam tseem ceeb nyob rau hauv lub zog cia substation
1. Kauj ruam -Up Transformer
Lub plawv ntawm ESS substation. Nws tsa qhov qis -voltage AC tso zis ntawm PCS (feem ntau 0.4–0.69 kV) rau daim phiaj hluav taws xob - feem ntau 10 kV, 20 kV lossis 33 kV - thiab nqis rov qab thaum them nyiaj. Ob qho tib si qhuav- hom thiab roj- immersed transformers muaj nyob ntawm qhov hluav taws kub- cov kev xav tau kev nyab xeeb thiab cov kab hauv zos.

GNEE Electric tsim cov khoom qhuav-hom transformers txog 5,000 kVA thiab roj-immersed transformers mus txog 10,000 kVA, npog daim phiaj- nplai thiab C&I lub zog cia cov haujlwm. Vim hais tias lub transformer yog inherently bidirectional, ib chav tsev tuav ob qho tib si them thiab tawm; kev tiv thaiv kev teeb tsa tau sib koom ua ke rau kev rov qab fais fab ntws.
2. MV thiab LV Switchgear
MV switchgear muab kev hloov pauv hauv Circuit Court, luv luv- kev sib cais ntawm kev sib cais thiab cov cuab yeej tiv thaiv ntawm kab hluav taws xob sab, suav nrog lub tshuab nqus tsev vacuum breakers, cais cov disconnectors, surge arresters thiab lub ntiaj teb hloov. LV switchgear tiv thaiv PCS- sab kev sib txuas. Compartmentalized hlau-kab switchgear tsim los rau IEC 62271-200 txwv tsis pub tshaj tawm thiab txhim kho arc-fault kev nyab xeeb thaum kho.

3. Huab cua-Resistant Enclosure
Lub kaw lus tiv thaiv tag nrho cov cuab yeej sab hauv tiv thaiv cov cua daj cua dub, cov dej ntsev ntawm ntug dej hiav txwv, cov daus hnyav, cov av noo siab thiab huab cua kub heev.
GNEE Electric siv cov pa roj carbon-steel shells nrog tshuaj tsuag txheej thiab galvanizing, ua tiav IP54, IP55 lossis IP65 ingress tiv thaiv, nrog tiv thaiv- kho corrosion raws ISO 12944 (C3-C5). Internal compartmentalization cais cov transformer, MV thiab LV zones kom muaj ib qho txhaum nyob rau hauv nws lub chamber.
4. Kev tiv thaiv, ntsuas thiab saib xyuas
Niaj hnub nimno lub zog cia substations integrates kev tiv thaiv relays, nyiaj tau los-qib zog ntsuas, lub zos HMI panels thiab SCADA/EMS- npaj kev sib txuas lus interfaces (IEC 61850, Modbus), ua kom tej thaj chaw deb saib xyuas, ua txhaum lub tswb thiab tsis muaj neeg saib xyuas. Cov cuab yeej pabcuam suav nrog kev tswj hwm huab cua, teeb pom kev zoo thiab cov khoom siv hluav taws xob / hluav taws xob cuam tshuam rau kev saib xyuas kev nyab xeeb.
Cov txiaj ntsig tseem ceeb ntawm Lub Zog Cia Substation
Kev xa tawm sai thiab luv dua qhov project ncua sij hawm
Lub Hoobkas sib dhos thiab ua ntej- kev sim xa khoom txo qis rau ntawm - chaw ua haujlwm pej xeem thiab lub sijhawm teeb tsa. Rau EPC cov neeg cog lus thiab cov neeg tsim khoom cia, qhov no ua rau txoj hauv kev mus rau txoj kab sib txuas thiab cov nyiaj tau los - ua haujlwm ntawm BESS cog.
Compact footprint
Compact modular layouts nyob hauv thaj av tsawg dua li cov chaw ua haujlwm sib txawv. GNEE Electric cov chav nyob yog cov tsawg tshaj plaws thiab lub teeb tshaj plaws ntawm qhov muaj peev xwm sib npaug hauv kev lag luam - qhov kev txiav txim siab kom zoo dua qhov chaw qhov project yog txwv, xws li C&I rooftops thiab densely npaj cog layouts.
Kev ntseeg siab thiab qis dua OPEX
Kev tsim khoom raws li lub Hoobkas ruaj khov muab cov khoom sib dhos zoo sib xws, thiab txhua lub tsev tau dhau los ua ntej - kev kuaj xa tuaj. Compartmentalized architecture txo qis kev tsis ua haujlwm ntawm cov saw hlau, txo qis - lub sij hawm tu tus nqi tshaj qhov kev cia khoom lub neej ua haujlwm.
Txhim khu kev ruaj ntseg ua haujlwm
Lub kaw lus tag nrho, muab faib tsim txwv tsis pub raug rau qhov chaw nyob; mechanical thiab hluav taws xob interlocks tiv thaiv kev nkag tsis raug thaum kho; arc-fault containment localizes short-circuit events in limited chambers, tiv thaiv cov neeg ua haujlwm thiab cov khoom muaj nqis.
Kev Tswj Thermal Efficiency
Cov ntawv thov kev siv hluav taws xob tso cov thermal kev ntxhov siab rau ntawm qhov chaw hloov hluav taws xob. GNEE Electric's patented sab saum toj- tshuab cua txias nrog baffle- coj cov cua ncig txhim kho cov cua sov kom tsis txhob muaj nqi ntxiv, ua kom lub tshuab hluav taws xob kub nce hauv qhov txwv (60 K / 65 K ib IEC 60076).
Bidirectional -Kev Npaj Npaj
Lub ESS substation yog engineered rau txuas ntxiv bidirectional fais fab hloov thaum lub sij hawm them thiab tawm, nrog kev tiv thaiv kev sib koom ua ke kom rov qab fais fab ntws. Fais fab- ntws kev taw qhia thiab qhov loj me tseem yog lub luag haujlwm ntawm PCS thiab cog kev tswj hwm hluav taws xob (EMS).
Modular Scalability
Lub tswv yim modular txhawb nqa kev nthuav dav: raws li cov nroj tsuag muaj peev xwm loj hlob, cov khoom siv substation ntxiv tuaj yeem muab ntxiv tsis yog kev tsim kho tag nrho, tiv thaiv thawj zaug peev.
Hom Daim Ntawv Thov Scenarios
- Kev siv hluav taws xob- nplai standalone BESS cov nroj tsuag- daim phiaj- teev cia rau cov kev cai zaus, ncov shaving thiab lub zog arbitrage, siv loj - muaj peev xwm cia lub zog substations rau centralized grid export.
- Rov ua dua tshiab -plus- khaws cia hybrids- co-nyob PV-plus- khaws cia thiab cua- ntxiv rau- cov nroj tsuag khaws cia sib koom ua ke MV kab sib txuas.
- Kev lag luam thiab kev lag luam ESS- tom qab- - 'meter' cia rau cov chaw tsim khoom, cov tsev lag luam thiab cov chaw ua si, feem ntau nrog cov thawv ntim khoom lossis caij tsheb kauj vab - mounted units.
- Microgrids thiab Island Grids- cia-raws li lub zog ntsuas nrog dub- pib muaj peev xwm.
- Cov kev pabcuam ntxiv- ceev- teb cov haujlwm khaws cia uas muab kev tswj hwm zaus thiab muaj peev xwm cia.

Kev txiav txim siab tseem ceeb thaum xaiv koj ESS substation
- Rated zog thiab muaj peev xwm (MW / MVA)- txhais cov transformer loj. GNEE Electric npog qhuav- hom mus txog 5,000 kVA thiab roj- raus mus txog 10,000 kVA ib chav tsev; cov nroj tsuag loj tuaj yeem ua haujlwm los ntawm ntau chav.
- Grid kev twb kev txuas voltage- 10 kV / 20 kV / 33 kV rau IEC kev lag luam; 6 kV / 10 kV rau Suav teb cov haujlwm.
- Transformer hom- qhuav- hom rau hluav taws- qhov chaw rhiab heev, sab hauv tsev lossis cov chaw muaj neeg coob coob; roj- raus rau tus nqi- siv hluav taws xob sab nraum zoov zoo - daim ntawv thov teev.
- Qhov chaw ib puag ncig- ambient kub, qhov siab (kev ntsuam xyuas yuav tsum tau derated saum 1,000 m ib IEC 60076 thiab IEC 62271-1), ntug dej hiav txwv ntsev tsuag, xuab zeb thiab hmoov av.
- Harmonic ib puag ncig- PCS- tsim kev sib haum xeeb yuav tsum raug ntsuas raws li IEC 61000; qhia kom meej cov kev xaiv lim los yog K- ntsuas transformer qhov twg yuav tsum tau los ntawm kab lis kev cai.
- Kev tiv thaiv hluav taws- roj teeb- sab tua hluav taws feem ntau yog muab los ntawm BESS tus neeg muag khoom; substation muab hluav taws kub - ntsuas qhov sib cais raws li IEC 62271-202.
- Ua raws li cov qauv- IEC 62271-202 (prefabricated substations), IEC 60076 (transformers), IEC 61439 (LV switchgear), ISO 12944 (kev tiv thaiv corrosion), ntxiv rau CE conformity (LVD 2014/35/EU thiab EMC 2014/2014)
Yog tias koj tab tom tsim cov nroj tsuag BESS lossis hloov kho qhov chaw cia khoom siv hluav taws xob uas twb muaj lawm thiab xav tau kev ua raws, tus nqi -cov chaw tsim hluav taws xob ua haujlwm tau zoo rau lub zog cia, GNEE Electric pab pawg neeg tsim khoom tuaj yeem npaj cov duab kos, cov ntawv qhia tshwj xeeb thiab cov lus sib tw.
Thov qhia cov ntaub ntawv hauv qab no txog qhov project:
- Kev ntsuas hluav taws xob thiab muaj peev xwm (MW / MWh)
- Daim phiaj kev sib txuas lub hom phiaj voltage
- Transformer hom nyiam (qhuav-hom / roj-immersed)
- Qhov chaw ib puag ncig profile (qhov siab, qhov kub thiab txias, ntug hiav txwv lossis suab puam)
- Yuav tsum muaj ntawv pov thawj
- Email:sales@gneeelectric.com
- WhatsApp pawg: +86 15824687445
FAQ
Q: Dab tsi yog qhov txawv ntawm qhov chaw cia khoom hluav taws xob thiab lub chaw faib khoom siv hluav taws xob?
A: Lub chaw nres tsheb ESS yog tsim los rau kev hloov hluav taws xob bidirectional, rau qhov kev sib tshuam ntawm PCS cov zis (suav nrog cov ntsiab lus sib haum xeeb) thiab rau kev txiav txim siab thermal thiab hluav taws tshwj xeeb rau cov nroj tsuag roj teeb. Cov chaw faib khoom raws li ib txwm yog tsim los rau ib qho -txoj kev muab khoom thauj.
Q: Puas yog prefabricated substation rau lub zog cia suav nrog PCS lossis roj teeb?
A: Tsis yog. Lub PCS (bidirectional AC / DC converter) thiab cov roj teeb racks yog cov tshuab cais. Lub substation muab cov kauj ruam - nce transformer, MV/LV switchgear thiab kev tiv thaiv uas txuas cov PCS tso zis rau hauv daim phiaj. Rau cov haujlwm uas xav tau kev daws teeb meem tag nrho, GNEE Electric kuj tseem muab tag nrho - hauv- ib lub zog cia chav sib txuas ua ke ntawm transformer thiab PCS hauv ib lub thawv.
Q: Tib lub chaw nres tsheb puas tuaj yeem tuav ob qho tib si them thiab tso tawm?
A: Yog. Lub transformer yog inherently bidirectional, thiab lub substation yog tsim los mus tas li ob - txoj kev fais fab mov nrog kev tiv thaiv kev sib koom tes rau lub hwj chim rov qab. Kev taw qhia thiab qhov loj ntawm lub zog ntws yog tswj los ntawm PCS thiab cov nroj tsuag EMS.
Q: Qhuav- hom lossis roj-immersed transformer - kuv yuav xaiv qhov twg?
A: Qhuav-hom transformers haum rau hluav taws- qhov chaw rhiab heev, sab hauv tsev lossis cov chaw muaj neeg coob thiab yuav tsum tsis muaj roj ntim. Roj-immersed transformers feem ntau raug nqi ntau dua- siv tau rau sab nraum zoov siv hluav taws xob- nplai daim ntawv thov thiab muaj txog li 10,000 kVA los ntawm GNEE Electric.
Q: Qhov siab siab cuam tshuam li cas rau kev tsim?
A: Tshaj li 1,000 m, transformer thiab switchgear ratings yuav tsum tau derated raws li IEC 60076 thiab IEC 62271-1. GNEE Electric teeb tsa cov qib rwb thaiv tsev thiab lub peev xwm txias rau qhov chaw siab.
Q: Ntev npaum li cas ntawm - qhov chaw teeb tsa siv sijhawm?
A: Tom qab lub hauv paus tiav, hoisting, cable txiav thiab commissioning feem ntau ua tiav nyob rau hauv ob peb hnub, piv rau ntau lub lis piam rau stick- ua substations.
GNEE Electric manufacturing highlights: IEC thiab CE conformity, transformer ntau lawm muaj peev xwm ntawm 2,400 units ib xyoos twg, raug xa mus txog li ob lub hlis rau tus qauv configurations, ib tug - xyoo export warranty (extendable mus rau 3 los yog 5 xyoo), thiab dawb online kev qhia thoob plaws hauv lub project.
Cim npe nrov: Tuam Tshoj prefabricated substation rau lub zog cia tshuab, Tuam Tshoj prefabricated substation rau lub zog cia tshuab manufacturers, lwm tus neeg, Hoobkas
You Might Also Like
Xa kev nug


















